EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Advancing descemetopexy with real-time intraoperative optical coherence tomography for failed Descemet membrane detachment repositioning

Jing-Hao Qu, Ying-Han Zhao, Zi-Jun Xie, Ge-Ge Xiao, Li-Xue Shuai, Shao-Feng Gu, Hai-Kun Wang, Rong-Mei Peng, Jing Hong

Indian Journal of Ophthalmology · 2026

DOI: 10.4103/ijo.ijo_1769_25 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indian Journal of Ophthalmology, 2026. Verfasst von Jing-Hao Qu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Peking University Third Hospital, Beijing, China. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Descemet Membrane, Visual Acuity, Corneal Diseases. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The aim of this study was to investigate the efficacy of real-time intraoperative optical coherence tomography (i-OCT) in improving the rate of Descemet membrane (DM) repositioning in cases of failed descemetopexy for Descemet membrane detachment (DMD).

Methods

We retrospectively reviewed the medical records and anterior segment optical coherence tomography images of patients for whom DMD repositioning failed and who visited our hospital between December 2023 and May 2025. All patients had complex DMD and underwent repositioning procedures guided by i-OCT. The causes of previous repositioning failures were analyzed on the basis of the i-OCT findings, and appropriate surgical maneuvers were employed to anatomically reposition the DM.

Results

Sixteen patients (6 males and 10 females; mean age 69.4 ± 9.5 years) were included. The number of previous repositioning attempts ranged from 1 to 3. Common causes of repositioning failure include residual viscoelastic material, DM adhesion to the iris or intraocular lens surface, and DM rigidity. Successful DM repositioning was achieved for all patients under i-OCT guidance. Postoperatively, significant improvements in best-corrected visual acuity, central corneal thickness, and intraocular pressure were observed.

Conclusion

Real-time i-OCT is a powerful method for improving the rate of DM repositioning in patients for whom descemetopexy previously failed. This method enables precise surgical interventions, leading to better anatomical outcomes. Future studies with larger cohorts are needed to further explore the potential of i-OCT in ophthalmic surgeries.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, Optical CoherenceDescemet MembraneVisual AcuityCorneal DiseasesHumansFemaleRetrospective StudiesMaleAgedMiddle AgedAged, 80 and overReoperationIntraoperative PeriodFollow-Up StudiesTreatment Failure

Stichwörter der Autor:innen

Descemet membrane detachmentdescemetopexyintraoperative OCT

Autor:innen und Institutionen

  • Department of Ophthalmology, Peking University Third Hospital, Beijing, China.
  • Department of Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, Beijing, China.

Zitieren

APA

Qu, J. H., Zhao, Y. H., Xie, Z. J., Xiao, G. G., Shuai, L. X., Gu, S. F., Wang, H. K., Peng, R. M., & Hong, J. (2026). Advancing descemetopexy with real-time intraoperative optical coherence tomography for failed Descemet membrane detachment repositioning. Indian Journal of Ophthalmology. https://doi.org/10.4103/ijo.ijo_1769_25

Vancouver

Qu JH, Zhao YH, Xie ZJ, Xiao GG, Shuai LX, Gu SF, et al. Advancing descemetopexy with real-time intraoperative optical coherence tomography for failed Descemet membrane detachment repositioning. Indian Journal of Ophthalmology. 2026. doi:10.4103/ijo.ijo_1769_25

BibTeX
@article{Qu2026,
  author = {Qu, Jing-Hao and Zhao, Ying-Han and Xie, Zi-Jun and Xiao, Ge-Ge and Shuai, Li-Xue and Gu, Shao-Feng and Wang, Hai-Kun and Peng, Rong-Mei and Hong, Jing},
  title = {Advancing descemetopexy with real-time intraoperative optical coherence tomography for failed Descemet membrane detachment repositioning},
  journal = {Indian Journal of Ophthalmology},
  year = {2026},
  doi = {10.4103/ijo.ijo_1769_25}
}
Kostenlos starten →