Innovative approaches to overcome intra-operative challenges using illumination

Sony Sinha, Prateek Nishant, Arvind Kumar Morya

Indian Journal of Ophthalmology · 2023-11 · 71 (11) · 3576-3577

DOI: 10.4103/ijo.ijo_1677_23 ↗

Kurz gefasst

Kommentar in der Zeitschrift Indian Journal of Ophthalmology, online erschienen am 20.10.2023. Verfasst von Sony Sinha und 2 weiteren Autor:innen. Beteiligte Einrichtung: Vitreo-Retina and Oculoplasty, All India Institute of Medical Sciences, Patna, Bihar, India. Hauptthemen laut MEDLINE: Lighting. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 9 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Kim et al. presented an innovative approach to phaco-emulsification in eyes with cataracts and coexisting iris challenges.[1] They demonstrated the use of a phaco-chopper with an illuminated tip which helps to locate it when it engages the deepest parts of the nucleus. The use of illuminated intra-ocular devices is not new; posterior segment surgery routinely uses a light probe because visualization of the retina is impossible without the same.[2] The innovation in this report lies in popularizing the use of the endo illuminator by incorporating it into something as routine as a chopper.[1] It is known that intra-ocular surgery in the presence of corneal opacity or haze, in which visualization of the anterior segment structures is compromised, is challenging.[3] In the author’s experience, a flashlight torch projected onto the temporal limbus, sometimes focused using a standard +20 Diopters lens, can be used to offer enhancement of the view in resource-limited settings, as was the case in some cataract camps in the bygone era. Recent improvement in this technique has been the incorporation of a non-invasive optical fiber used as the only light source in performing phaco-emulsification in patients with hazy deep anterior lamellar keratoplasty (DALK) grafts, as reported by Lin et al. As in their report, adjustment of the surgical microscope to a smaller aperture and higher coaxial illumination provides a better depth of field.[4] This has been the concept behind recently introduced stereo-coaxial red-glow enhancing devices mounted near the microscope objective. Alternative external devices for the enhancement of the intra-operative view include slit illuminators. Slit-projecting systems have been shown to reduce glare, enhance the red reflex, and improve depth perception in intra-ocular surgery including phaco-emulsification.[5] Nowadays, the use of 23-gauge, 25-gauge, or 27-gauge endo illuminators introduced into the eye is common and has been demonstrated extensively for anterior segment surgery in the presence of hazy media. Intra-vitreal or intra-cameral illumination (through trocar entry or limbal paracentesis, respectively) has been shown to result in better visualization of the margin of anterior capsulorrhexis and better assessment of the depth of impalement of the nucleus and of the site of chopping. Khokhar et al. have reported the routine use of the endo illuminator during pediatric cataract surgery for intra-operative posterior segment evaluation using wide-angle viewing lenses as well as in complicated situations encountered therein, such as Peter’s anomaly with buphthalmos, and iris abnormalities with 360-degrees posterior and mid-peripheral anterior synechiae.[6] In many cases, the chandelier system has also been incorporated for the same purpose, with the advantage of being self-retaining, so that the surgeon may perform bimanual procedures and an assistant is not engaged.[3] The endoscopic vitrectomy system, with its steep learning curve, is a newer addition to the armamentarium for intra-ocular surgery in the presence of distorted ocular anatomy. Although it completely bypasses the need for a temporary keratoprosthesis to clear the field of view in the most distressing corneal opacities, this system carries the caveats of having a different ‘tunnel-like’ perspective in terms of surgical view and no direct means for perception of depth of the instrument tip and its distance from the retina, thereby increasing the probability of iatrogenic retinal injury.[7] Newer intra-ocular illuminators use novel light-emitting diode (LED) systems, developed by integration of microscopic surface mount device (micro-SMD) LEDs and surface-mounted LEDs (SM-LED) into trocars and diaphanoscopes.[8] Koelbl et al. have reported the use of a light-source-on-tip LED endo illuminator, which offers the combined advantages of chandelier wide-angle illumination and an adjustable endo illuminator.[9] The popularization of these novel devices will surely revolutionize the standard of care in the hands of novice as well as experienced surgeons. But this is not without a word of caution regarding the possible retinal toxicity of increased intra-ocular irradiance.[8] Recent research has shown that the “allowed safe exposure times” for endo illumination systems are based on mathematical calculations on eye models and may not accurately reflect the actual intra-operative exposure dose. The potential phototoxic hazard to the retina is higher, particularly at wavelengths shorter than 500 nm. The cumulative exposure is based on the distance of the light source from the retina, which varies throughout the surgery. Bringing the light source closer to the retina exponentially raises the risk of phototoxicity.[2,8] In conclusion, necessity is the mother of innovation (or invention, as the case may be). One must be aware of developments in the gamut of tools available for the ophthalmic surgeon who is challenged with more and more complex situations every day. Whereas modern illumination systems offer several advantages, they are not without risks which must be carefully examined on a case-to-case basis and the surgical approach individualized in the patient’s best interests.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LightingHumansPhotic Stimulation

Autor:innen und Institutionen

  • Vitreo-Retina and Oculoplasty, All India Institute of Medical Sciences, Patna, Bihar, India.
  • Department of Ophthalmology, All India Institute of Medical Sciences, Patna, Bihar, India.
  • Cataract, Glaucoma, Refractive, Squint, Paediatric Ophthalmology and Medical Retina Services, All India Institute of Medical Sciences, Bibinagar, Hyderabad, Telangana, India.

Zitieren

APA

Sinha, S., Nishant, P., & Morya, A. K. (2023). Innovative approaches to overcome intra-operative challenges using illumination. Indian Journal of Ophthalmology, 71(11), 3576-3577. https://doi.org/10.4103/ijo.ijo_1677_23

Vancouver

Sinha S, Nishant P, Morya AK. Innovative approaches to overcome intra-operative challenges using illumination. Indian Journal of Ophthalmology. 2023;71(11):3576-3577. doi:10.4103/ijo.ijo_1677_23

BibTeX
@article{Sinha2023,
  author = {Sinha, Sony and Nishant, Prateek and Morya, Arvind Kumar},
  title = {Innovative approaches to overcome intra-operative challenges using illumination},
  journal = {Indian Journal of Ophthalmology},
  year = {2023},
  volume = {71},
  number = {11},
  pages = {3576--3577},
  doi = {10.4103/ijo.ijo_1677_23}
}
Kostenlos starten →