EUVIMEDEUVIMED entdecken
VergleichsstudieBeobachtungsstudieOpen Access · CC BY-NC-ND 4.0

Comparison of ocular biometry and refraction measurements among myopic children using myopia master with IOL master 700 and NIDEK ARK-500 autorefractor

Vinay Gupta, Amber Amar Bhayana, Jyoti Rawat, Abhyuday Saxena, Rebika Dhiman, Swati Phuljhele, Rohit Saxena

Indian Journal of Ophthalmology · 2026-04 · 74 (4) · 576-579

DOI: 10.4103/ijo.ijo_1476_25 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Indian Journal of Ophthalmology, online erschienen am 26.03.2026. Verfasst von Vinay Gupta und 6 weiteren Autor:innen. Beteiligte Einrichtung: Dr. R. P. Centre for Ophthalmic Sciences, AIIMS, New Delhi, India. Hauptthemen laut MEDLINE: Biometry, Refraction, Ocular, Myopia, Axial Length, Eye. Die Arbeit nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This comparative study aimed to evaluate interchangeability of the Myopia Master, IOL Master 700, and Nidek ARK500 autorefractometer for axial length, keratometry, and autorefraction measurements among myopic children.

Methods

This prospective, observational, single-blinded study included children aged 5 to 15 years, with myopia ≥-0.5D. The axial length and keratometry were measured using Myopia Master and IOL Master 700. Cycloplegic autorefraction with keratometry was measured using Myopia Master and NIDEK ARK500 autorefractor. The primary outcome was to assess the agreement of measurements between the devices.

Results

A total of 35 participants with a mean age of 10.2 ± 2.8 years (57% male) were enrolled. The Myopia Master measured axial length 0.01 mm shorter and keratometry 0.087 D and 0.12 D flatter in the two meridians compared to the IOL Master 700. The spherical refractive error was 0.086 D more myopic than that from the NIDEK ARK500 autorefractometer, while cylindrical error showed no difference. All parameters demonstrated strong correlations (r: 0.96–0.99).

Conclusions

The Myopia Master is interchangeable with the NIDEK ARK500 autorefractometer for refractive error assessment and with the IOL Master 700 for keratometry and axial length measurements in pediatric myopic subjects. This is supported by minimal mean bias and narrow 95% limits of agreement. Thus, it could serve as reliable tool for myopia management.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BiometryRefraction, OcularMyopiaAxial Length, EyeCorneaHumansChildMaleFemaleProspective StudiesChild, PreschoolAdolescentSingle-Blind MethodReproducibility of ResultsEquipment Design

Stichwörter der Autor:innen

Axial lengthIOL mastermyopiamyopia masterocular biometry

Autor:innen und Institutionen

  • Dr. R. P. Centre for Ophthalmic Sciences, AIIMS, New Delhi, India.

Zitieren

APA

Gupta, V., Bhayana, A. A., Rawat, J., Saxena, A., Dhiman, R., Phuljhele, S., & Saxena, R. (2026). Comparison of ocular biometry and refraction measurements among myopic children using myopia master with IOL master 700 and NIDEK ARK-500 autorefractor. Indian Journal of Ophthalmology, 74(4), 576-579. https://doi.org/10.4103/ijo.ijo_1476_25

Vancouver

Gupta V, Bhayana AA, Rawat J, Saxena A, Dhiman R, Phuljhele S, et al. Comparison of ocular biometry and refraction measurements among myopic children using myopia master with IOL master 700 and NIDEK ARK-500 autorefractor. Indian Journal of Ophthalmology. 2026;74(4):576-579. doi:10.4103/ijo.ijo_1476_25

BibTeX
@article{Gupta2026,
  author = {Gupta, Vinay and Bhayana, Amber Amar and Rawat, Jyoti and Saxena, Abhyuday and Dhiman, Rebika and Phuljhele, Swati and Saxena, Rohit},
  title = {Comparison of ocular biometry and refraction measurements among myopic children using myopia master with IOL master 700 and NIDEK ARK-500 autorefractor},
  journal = {Indian Journal of Ophthalmology},
  year = {2026},
  volume = {74},
  number = {4},
  pages = {576--579},
  doi = {10.4103/ijo.ijo_1476_25}
}
Kostenlos starten →