The Lumi-Indent: A novel illuminated scleral depressor and a comprehensive review of existing illuminated scleral depression techniques
Indian Journal of Ophthalmology · 2025
DOI: 10.4103/ijo.ijo_1245_25 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Indian Journal of Ophthalmology, 2025. Verfasst von Prithvi Chandrakanth und 2 weiteren Autor:innen. Beteiligte Einrichtung: Consultant Vitreoretinal Surgeon, Vitreoretinal Services, Dr. Chandrakanth Nethralaya, Kozikode, Kerala, India. Hauptthemen laut MEDLINE: Sclera, Vitrectomy, Lighting. Die Arbeit nennt 5 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Themen: Depression
Abstract (Originalsprache)
Three-port pars plana vitrectomy (PPV) requires thorough visualization of the peripheral vitreous base, typically achieved using scleral depression. Traditional methods, involving either a trained assistant or chandelier illumination, are limited by cost, assistant dependency, and inconsistent visualization. In this article, we describe a “do it yourself”(DIY) cost-effective, improvised illuminated scleral depressor—“The Lumi-Indent”—created by inserting a 25-gauge endoilluminator into the cap of a disposable hypodermic needle and securing it with sterile tape. The device was used in 50 consecutive vitreoretinal surgeries with 360° vitreous base shaving. No intraoperative complications were noted. We also review existing techniques, including Veckeneer’s Tyndall effect-enhanced transillumination with triamcinolone and PFCL; Bamonte’s simplified method using a venflon cannula sleeve; Mandelcorn’s light pipe and finger-mounted ring depressor; Todorich’s digital heads-up system with a molded adapter tip; and Tan’s cotton swab-modified depressor. While each approach improves surgeon independence and peripheral visualization, many require either costly equipment or present structural limitations. Our Lumi-Indent depressor offered consistent illumination, scleral rigidity, and smooth conjunctival navigation, without the risk of bending or damaging the light pipe. Its negligible cost and simplicity make it an ideal solution for high-volume or resource-limited settings. In conclusion, the Lumi-Indent is a safe, frugal, and efficient tool for assistant-free vitreous base shaving, expanding the accessibility of advanced surgical techniques.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Consultant Vitreoretinal Surgeon, Vitreoretinal Services, Dr. Chandrakanth Nethralaya, Kozikode, Kerala, India.
- Consultant vitreoretinal Surgeon, Vitreoretinal Services, Amita Eye Care, Thiruvalla, Kerala, India.
- Consultant cataract and refractive surgeon, Cataract and Refractive services, Dr. Chandrakanth Nethralaya, Kozikode, Kerala, India.
Zitieren
APA
Chandrakanth, P., Verghese, S., & Chandrakanth, K. (2025). The Lumi-Indent: A novel illuminated scleral depressor and a comprehensive review of existing illuminated scleral depression techniques. Indian Journal of Ophthalmology. https://doi.org/10.4103/ijo.ijo_1245_25
Vancouver
Chandrakanth P, Verghese S, Chandrakanth K. The Lumi-Indent: A novel illuminated scleral depressor and a comprehensive review of existing illuminated scleral depression techniques. Indian Journal of Ophthalmology. 2025. doi:10.4103/ijo.ijo_1245_25
BibTeX
@article{Chandrakanth2025,
author = {Chandrakanth, Prithvi and Verghese, Shishir and Chandrakanth, K},
title = {The Lumi-Indent: A novel illuminated scleral depressor and a comprehensive review of existing illuminated scleral depression techniques},
journal = {Indian Journal of Ophthalmology},
year = {2025},
doi = {10.4103/ijo.ijo_1245_25}
}
EUVIMED