EUVIMEDEUVIMED entdecken
Open Access

Comparison between ocular biometry parameters in patients with unilateral congenital glaucoma

Premanand Chandran, Chavan Sneha, Sunada Subramanian, Ganesh V Raman

Indian Journal of Ophthalmology · 2023-08 · 71 (8) · 2962-2966

DOI: 10.4103/ijo.ijo_122_23 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indian Journal of Ophthalmology, online erschienen am 01.08.2023. Verfasst von Premanand Chandran und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Glaucoma, Aravind Eye Hospital, Coimbatore, Tamil Nadu, India. Hauptthemen laut MEDLINE: Glaucoma, Trabeculectomy. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To compare the axial length (AL) and corneal diameter between glaucomatous eye (GE) and fellow normal eye (NE) in patients with unilateral congenital glaucoma and to obtain a normative database for ocular growth among Indian children below 3 years of age.

Methods

Retrospective longitudinal study. Patients who had a follow-up of 3 years from diagnosis with ocular biometry parameters being recorded at least thrice (once a year) and fellow eye being normal were included. Data collected were age, gender, intraocular pressure (IOP), AL, corneal diameter, optic disc findings, diagnosis, and surgery details.

Results

Eleven patients were analyzed. All GE underwent combined trabeculotomy with trabeculectomy. Mean (SD) baseline IOP, AL, and corneal diameter were 17.1 (6.7) mmHg, 18.9 (1.1) mm and 12 (0.91) mm in GE, and 11.1 (3.8) mmHg, 17.8 (0.44) mm, and 10.5 (0.58) mm in NE, respectively. Increase in AL was 3.1 mm in the first year followed by 0.6 mm in second year and 0.4 mm in third year in GE compared to 2.6, 0.6, and 0.5 mm in NE, respectively. Corneal diameter increased by 1.1 mm in GE in the first year and remained stable thereafter compared to 0.7 mm in first year followed by 0.3 mm in second year and stable thereafter in NE. The percentage of success was 73% at 3 years.

Conclusion

Axial length and corneal diameter were higher in GE than NE at all-time points. With prompt intervention, the growth curve of the GE was made parallel to that of NE.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GlaucomaTrabeculectomyChildHumansRetrospective StudiesLongitudinal StudiesCorneaIntraocular PressureBiometryTreatment OutcomeFollow-Up Studies

Stichwörter der Autor:innen

Axial lengthcongenital glaucomacorneal diameterintraocular pressure

Autor:innen und Institutionen

  • Department of Glaucoma, Aravind Eye Hospital, Coimbatore, Tamil Nadu, India.

Zitieren

APA

Chandran, P., Sneha, C., Subramanian, S., & Raman, G. V. (2023). Comparison between ocular biometry parameters in patients with unilateral congenital glaucoma. Indian Journal of Ophthalmology, 71(8), 2962-2966. https://doi.org/10.4103/ijo.ijo_122_23

Vancouver

Chandran P, Sneha C, Subramanian S, Raman GV. Comparison between ocular biometry parameters in patients with unilateral congenital glaucoma. Indian Journal of Ophthalmology. 2023;71(8):2962-2966. doi:10.4103/ijo.ijo_122_23

BibTeX
@article{Chandran2023,
  author = {Chandran, Premanand and Sneha, Chavan and Subramanian, Sunada and Raman, Ganesh V},
  title = {Comparison between ocular biometry parameters in patients with unilateral congenital glaucoma},
  journal = {Indian Journal of Ophthalmology},
  year = {2023},
  volume = {71},
  number = {8},
  pages = {2962--2966},
  doi = {10.4103/ijo.ijo_122_23}
}
Kostenlos starten →