EUVIMEDEUVIMED entdecken
BeobachtungsstudieOpen Access

Visual performance and patient satisfaction with AcrySof® IQ Vivity® IOL: Experience from a tertiary care center in central India

Purendra Bhasin, Deepayan Sarkar, Priyamvada Bhasin, Praveen P Dhanapal, Gopal N Ubhal, Meenu Bhargava

Indian Journal of Ophthalmology · 2024

DOI: 10.4103/ijo.ijo_1018_23 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Indian Journal of Ophthalmology, 2024. Verfasst von Purendra Bhasin und 5 weiteren Autor:innen. Beteiligte Einrichtung: Ratan Jyoti Netralaya, Gwalior, Madhya Pradesh, India. Hauptthemen laut MEDLINE: Lenses, Intraocular, Phacoemulsification, Myopia. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 8 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To study the visual outcomes and patient satisfaction profile among patients post phacoemulsification with the Vivity intraocular lens (IOL) implantation.

Method

This was a hospital-based, prospective, observational study cons isting of 64 study subjects who were followed up for 1 month to look for the objective and subjective aspects of visual outcomes of Vivity IOLs. Objective parameters included distance vision, intermediate vision, near vision, and contrast-sensitivity, whereas subjective parameters were assessed using the modified Catquest 9SF Questionnaire.

Results

Among the total study population, 82.5% were males and 17.5% were females, the most common age group was 41–50 years. In addition, 93.6% had a distance visual acuity of 6/9 or better, 93.7% had an intermediate vision of N18 or better, whereas 50.8% had a near vision of N18 or better. Good contrast sensitivity was reported among 79.4% of subjects, and 95.2% of study subjects were comfortable with distance vision, whereas 74.6% and 22.2% were comfortable with intermediate and near vision, respectively. Only two patients complained of glare, whereas none complained of halos and starbursts. A total of 88.8% of study subjects were satisfied with their postoperative visual outcomes, whereas 87.3% were willing to Vivity IOL in the other eye or were willing to refer this IOL to others.

Conclusion

The study demonstrated a good distance and intermediate visual acuity post-Vivity IOL implantation, whereas near activities mostly required the use of near-addition glasses, though requiring lesser near-addition power.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lenses, IntraocularPhacoemulsificationMyopiaMaleFemaleHumansAdultMiddle AgedLens Implantation, IntraocularPatient SatisfactionProspective StudiesTertiary Care CentersIndiaProsthesis Design

Autor:innen und Institutionen

  • Ratan Jyoti Netralaya, Gwalior, Madhya Pradesh, India.

Zitieren

APA

Bhasin, P., Sarkar, D., Bhasin, P., Dhanapal, P. P., Ubhal, G. N., & Bhargava, M. (2024). Visual performance and patient satisfaction with AcrySof® IQ Vivity® IOL: Experience from a tertiary care center in central India. Indian Journal of Ophthalmology. https://doi.org/10.4103/ijo.ijo_1018_23

Vancouver

Bhasin P, Sarkar D, Bhasin P, Dhanapal PP, Ubhal GN, Bhargava M. Visual performance and patient satisfaction with AcrySof® IQ Vivity® IOL: Experience from a tertiary care center in central India. Indian Journal of Ophthalmology. 2024. doi:10.4103/ijo.ijo_1018_23

BibTeX
@article{Bhasin2024,
  author = {Bhasin, Purendra and Sarkar, Deepayan and Bhasin, Priyamvada and Dhanapal, Praveen P and Ubhal, Gopal N and Bhargava, Meenu},
  title = {Visual performance and patient satisfaction with AcrySof® IQ Vivity® IOL: Experience from a tertiary care center in central India},
  journal = {Indian Journal of Ophthalmology},
  year = {2024},
  doi = {10.4103/ijo.ijo_1018_23}
}
Kostenlos starten →