EUVIMEDEUVIMED entdecken
Open Access

A comparison of the quality of images of chest X-ray between handheld portable digital X-ray & routinely used digital X-ray machine

Raj Kamal, Manjula Singh, Sudipto Roy, Tulsi Adhikari, Anil Kumar Gupta, Hari Singh, Vishnu Vardhan Rao, Samiran Panda, A M Khan, Balram Bhargava

Indian Journal of Medical Research · 2023

DOI: 10.4103/ijmr.ijmr_845_22 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indian Journal of Medical Research, 2023. Verfasst von Raj Kamal und 9 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Division, ICMR-National Jalma Institute for Leprosy & Other Mycobacterial Diseases, Agra, Uttar Pradesh, India. Hauptthemen laut MEDLINE: Radiography, Thoracic, Tuberculosis, Pulmonary. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 7 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background & objectives: Chest X-ray (CXR) is an important screening tool for pulmonary tuberculosis (TB). Accessibility to CXR facilities in difficult-to-reach and underserved populations is a challenge. This can potentially be overcome by deploying digital X-ray machines that are portable. However, these portable X-ray machines need to be validated before their deployment in the field. Here, we compare the image quality of CXR taken by a newly developed handheld X-ray machine with routinely used reference digital X-ray machine through the conduct of a feasibility study.

Methods

A total of 100 participants with suspected pulmonary TB were recruited from the outpatient departments of a medical college and a community health centre in Agra. Each participant underwent CXR twice, once with each machine. Both sets of de-identified images were independently read by two radiologists, who were blinded to the type of X-ray machine used. The primary outcome was agreement between image qualities produced by these two machines.

Results

The intra-observer (radiologist) agreements regarding the status of the 15 CXR parameters ranged between 74 per cent and 100 per cent, with an unweighted mean of 87.2 per cent (95% confidence interval: 71.5-100). The median Cohen’s kappa values for intra-observer agreement were 0.62 and 0.67 for radiologists 1 and 2, respectively. In addition, on comparison of the overall median score of quality of the image, the handheld machine images had a higher score for image quality. Interpretation & conclusions: The current study shows that a handheld X-ray machine, which is easy to use and can potentially be carried to any area, produces X-ray images with quality that is comparable to digital X-ray machines routinely used in health facilities.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiography, ThoracicTuberculosis, PulmonaryHumansX-RaysSensitivity and Specificity

Stichwörter der Autor:innen

Agreementcomparisonhard-to-reachportable X-rayquality

Autor:innen und Institutionen

  • Clinical Division, ICMR-National Jalma Institute for Leprosy & Other Mycobacterial Diseases, Agra, Uttar Pradesh, India.
  • Unit of TB, Leprosy & TH (ECD), Indian Council of Medical Research, New Delhi, India.
  • Clinical Studies and Trials Unit, Indian Council of Medical Research, New Delhi, India.
  • ICMR-National Institute of Medical Statistics, New Delhi, India.
  • Department of Radiology, F. H. Medical College, Agra, Uttar Pradesh, India.
  • S. N. Medical College, Agra, Uttar Pradesh, India.

Zitieren

APA

Kamal, R., Singh, M., Roy, S., Adhikari, T., Gupta, A. K., Singh, H., Rao, V. V., Panda, S., Khan, A. M., & Bhargava, B. (2023). A comparison of the quality of images of chest X-ray between handheld portable digital X-ray & routinely used digital X-ray machine. Indian Journal of Medical Research. https://doi.org/10.4103/ijmr.ijmr_845_22

Vancouver

Kamal R, Singh M, Roy S, Adhikari T, Gupta AK, Singh H, et al. A comparison of the quality of images of chest X-ray between handheld portable digital X-ray & routinely used digital X-ray machine. Indian Journal of Medical Research. 2023. doi:10.4103/ijmr.ijmr_845_22

BibTeX
@article{Kamal2023,
  author = {Kamal, Raj and Singh, Manjula and Roy, Sudipto and Adhikari, Tulsi and Gupta, Anil Kumar and Singh, Hari and Rao, Vishnu Vardhan and Panda, Samiran and Khan, A M and Bhargava, Balram},
  title = {A comparison of the quality of images of chest X-ray between handheld portable digital X-ray & routinely used digital X-ray machine},
  journal = {Indian Journal of Medical Research},
  year = {2023},
  doi = {10.4103/ijmr.ijmr_845_22}
}
Kostenlos starten →