EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieVergleichsstudie

Comparative Evaluation of Normal Saline Gel and Ozone Therapy on Soft and Hard Tissue Health in Dental Implant Surgery

Abhay Dixit, Bhaskar Agarwal, Kamleshwar Singh, Pooran Chand, Jitendra Rao, Niraj Mishra

Indian Journal of Dental Research · 2024

DOI: 10.4103/ijdr.ijdr_591_23 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Indian Journal of Dental Research, 2024. Verfasst von Abhay Dixit und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, King George's Medical University, Lucknow, Uttar Pradesh, India. Hauptthemen laut MEDLINE: Ozone, Gels, C-Reactive Protein, Saline Solution. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 17 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

To comparatively evaluate the effect of normal saline gel and ozonated saline-ozonated gel (ozone therapy) on pain, inflammation, soft tissue, and crestal bone loss in dental implant surgery. Methods and Material: Forty adult patients scheduled to undergo implant were randomized into two groups: Twenty patients ( n = 20) received ozone therapy and controls ( n = 20) received normal saline and gel during implant placement. Inflammation and pain were noted at days 1 and 7 and 3 month intervals by estimating C-reactive protein (CRP) levels and assessing visual analogue scale (VAS) scores. At 3 months, soft tissue outcomes were noted in terms of plaque index, gingival index, and pocket depth, while crestal bone loss was noted via a radiograph.

Results

Mean CRP levels were significantly higher in the control group as compared to that in the case group on day 1 and day 7 follow-ups ( P < 0.05). Mean VAS scores for pain were also lower in the case group as compared to the control group at all follow-ups, but the difference was significant statistically only at day 1 ( P = 0.061). The plaque index was significantly lower in the case group as compared to the control group ( P = 0.011) at final follow-up. No significant difference between two groups was observed for crestal bone loss.

Conclusions

Ozone therapy during implant placement was effective in reduction of pain, systemic inflammation, and plaque deposition in dental implant patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OzoneGelsC-Reactive ProteinSaline SolutionHumansMaleFemaleAdultMiddle AgedDental ImplantsDental Plaque IndexAlveolar Bone LossPeriodontal IndexPain MeasurementDental ImplantationInflammation

Substanzen

OzoneGelsC-Reactive ProteinSaline SolutionDental Implants

Autor:innen und Institutionen

  • Department of Prosthodontics, King George's Medical University, Lucknow, Uttar Pradesh, India.

Zitieren

APA

Dixit, A., Agarwal, B., Singh, K., Chand, P., Rao, J., & Mishra, N. (2024). Comparative Evaluation of Normal Saline Gel and Ozone Therapy on Soft and Hard Tissue Health in Dental Implant Surgery. Indian Journal of Dental Research. https://doi.org/10.4103/ijdr.ijdr_591_23

Vancouver

Dixit A, Agarwal B, Singh K, Chand P, Rao J, Mishra N. Comparative Evaluation of Normal Saline Gel and Ozone Therapy on Soft and Hard Tissue Health in Dental Implant Surgery. Indian Journal of Dental Research. 2024. doi:10.4103/ijdr.ijdr_591_23

BibTeX
@article{Dixit2024,
  author = {Dixit, Abhay and Agarwal, Bhaskar and Singh, Kamleshwar and Chand, Pooran and Rao, Jitendra and Mishra, Niraj},
  title = {Comparative Evaluation of Normal Saline Gel and Ozone Therapy on Soft and Hard Tissue Health in Dental Implant Surgery},
  journal = {Indian Journal of Dental Research},
  year = {2024},
  doi = {10.4103/ijdr.ijdr_591_23}
}
Kostenlos starten →