Altering the Angle of Attachment for Fixed Functional Appliances to Control Lower Incisor Proclination - An Evaluative Study
Indian Journal of Dental Research · 2026
DOI: 10.4103/ijdr.ijdr_242_25 ↗Kurz gefasst
Fallbericht in der Zeitschrift Indian Journal of Dental Research, 2026. Verfasst von Mudita Srivastava und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, Institute of Dental Studies and Technology, Modinagar, Uttar Pradesh, India. Hauptthemen laut MEDLINE: Incisor, Malocclusion, Angle Class II, Orthodontic Appliances, Functional. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Aims
The management of Class II malocclusion is challenging in growing patients, where the objective is to modulate skeletal growth rather than dentoalveolar correction only. Fixed functional appliances (FFA) have become a cornerstone in treating Class II malocclusions, offering an efficient alternative for mandibular advancement in non-compliant patients. However, one side effect of FFA is the proclination of lower incisors, which may require careful management through biomechanical control. Materials and Methods: The present study analysed the impact of altering the angle of FFA attachment on proclination of lower incisors, using mathematical modelling and clinical outcomes from two orthodontically treated cases. The FFA was placed from the maxillary first molar tube to the lower archwire, distal to the mandibular first premolar in a short attachment and distal to the mandibular canine in a long attachment case.
Results
The mathematical evaluation of the force vectors with long and short attachments of FFA revealed that the short attachment delivered 6 g less horizontal force and 20 g more intrusive force, along with six times more moment, in comparison to the long attachment. The clinical outcomes of the orthodontically treated cases indicated proclination of the lower incisors in both cases.
Conclusion
Altering the angle of attachment altered the vector of forces applied to the lower incisors, leading to a more intrusive force in the case of short-attachment FFA. However, future research with a larger, controlled sample is required to establish the extent and nature of the impact.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Orthodontics, Institute of Dental Studies and Technology, Modinagar, Uttar Pradesh, India.
- Department of Orthodontics and Dentofacial Orthopedics, Manav Rachna Dental College, Manav Rachna International Institute of Research and Studies, Faridabad, Haryana, India.
- Department of Orthodontics, CES University, Medellin, Colombia.
Zitieren
APA
Srivastava, M., Batra, P., Aziz, S. B., & Roldan, S. I. (2026). Altering the Angle of Attachment for Fixed Functional Appliances to Control Lower Incisor Proclination - An Evaluative Study. Indian Journal of Dental Research. https://doi.org/10.4103/ijdr.ijdr_242_25
Vancouver
Srivastava M, Batra P, Aziz SB, Roldan SI. Altering the Angle of Attachment for Fixed Functional Appliances to Control Lower Incisor Proclination - An Evaluative Study. Indian Journal of Dental Research. 2026. doi:10.4103/ijdr.ijdr_242_25
BibTeX
@article{Srivastava2026,
author = {Srivastava, Mudita and Batra, Puneet and Aziz, Sana Bint and Roldan, Samuel I},
title = {Altering the Angle of Attachment for Fixed Functional Appliances to Control Lower Incisor Proclination - An Evaluative Study},
journal = {Indian Journal of Dental Research},
year = {2026},
doi = {10.4103/ijdr.ijdr_242_25}
}
EUVIMED