EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyseOpen Access · CC BY-NC-SA 4.0

Application efficacy of dural puncture epidural versus traditional combined spinal epidural for labour analgesia: A systematic review and meta-analysis with trial sequential analysis

Junjun Qin iD, Weili Zhou iD, Zhengwei Chen iD, Changlin He iD, Jiasen Ma iD

Indian Journal of Anaesthesia · 2025-10 · 69 (10) · 999-1011

DOI: 10.4103/ija.ija_802_25 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Indian Journal of Anaesthesia, online erschienen am 05.09.2025. Verfasst von Junjun Qin und 4 weiteren Autor:innen. Beteiligte Einrichtung: Doctor of Medicine, Department of Anesthesiology, Affiliated Hospital of Hangzhou Normal University, Hangzhou, Zhejiang, China. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Aims: This study aimed to systematically evaluate the effectiveness and safety of dural puncture epidural (DPE) and combined spinal epidural (CSE) for labour analgesia in parturients.

Methods

Searches were performed in PubMed, Embase, Web of Science, Cochrane Library, CNKI, Wanfang Database, VIP Database, and CBM Database up to June 2025 to identify randomised controlled trials (RCTs) investigating the application of DPE and CSE techniques for labour analgesia in parturients. Data from eligible studies were pooled to calculate the combined standardised mean difference (SMD) or risk ratio (RR).

Results

Eleven studies with 1461 parturients were included. DPE had higher visual analogue scale (VAS) pain scores at 10 min [SMD: 0.60; 95% confidence interval (CI): 0.24, 0.95; P = 0.001; I 2 = 76%] compared to CSE but fewer parturients requiring physician top-up boluses (RR = 0.64; 95% CI: 0.46, 0.88; P = 0.006; I 2 = 11%). It also showed significantly lower incidences of abnormal foetal heart rate patterns (RR = 0.27; 95% CI: 0.16, 0.44; P < 0.001; I 2 = 0%), pruritus (RR = 0.27; 95% CI: 0.14, 0.53; P < 0.001; I 2 = 54%), and maternal hypotension (RR = 0.36; 95% CI: 0.15, 0.89; P = 0.030; I 2 = 74%). No significant intergroup differences were found in first-stage labour duration, neonatal Apgar scores, or adverse reactions. The trial sequential analysis suggested the need for further data.

Conclusion

Compared with CSE, although DPE has a slower onset of analgesia, it may provide more reliable analgesic effects and result in lower incidence rates of adverse reactions in both parturients and foetuses. Substantial heterogeneity in some outcomes, driven by clinical heterogeneity including dose variations and limited studies, warrants cautious interpretation.

Schlagwörter

Stichwörter der Autor:innen

Anaesthesiacombined spinal epiduraldural puncture epidurallabourlabour analgesiameta-analysisobstetricparturientspinal

Autor:innen und Institutionen

  • Doctor of Medicine, Department of Anesthesiology, Affiliated Hospital of Hangzhou Normal University, Hangzhou, Zhejiang, China.
  • Head Nurse, Department of Anesthesiology, Affiliated Hospital of Hangzhou Normal University, Hangzhou, Zhejiang, China.
  • Professor, Department of Anesthesiology, Affiliated Hospital of Hangzhou Normal University, Hangzhou, Zhejiang, China.

ORCID-Profile: Junjun Qin, Weili Zhou, Zhengwei Chen, Changlin He, Jiasen Ma

Zitieren

APA

Qin, J., Zhou, W., Chen, Z., He, C., & Ma, J. (2025). Application efficacy of dural puncture epidural versus traditional combined spinal epidural for labour analgesia: A systematic review and meta-analysis with trial sequential analysis. Indian Journal of Anaesthesia, 69(10), 999-1011. https://doi.org/10.4103/ija.ija_802_25

Vancouver

Qin J, Zhou W, Chen Z, He C, Ma J. Application efficacy of dural puncture epidural versus traditional combined spinal epidural for labour analgesia: A systematic review and meta-analysis with trial sequential analysis. Indian Journal of Anaesthesia. 2025;69(10):999-1011. doi:10.4103/ija.ija_802_25

BibTeX
@article{Qin2025,
  author = {Qin, Junjun and Zhou, Weili and Chen, Zhengwei and He, Changlin and Ma, Jiasen},
  title = {Application efficacy of dural puncture epidural versus traditional combined spinal epidural for labour analgesia: A systematic review and meta-analysis with trial sequential analysis},
  journal = {Indian Journal of Anaesthesia},
  year = {2025},
  volume = {69},
  number = {10},
  pages = {999--1011},
  doi = {10.4103/ija.ija_802_25}
}
Kostenlos starten →