The validity of thoracic fluid content measurement as a non-invasive predictor of weaning critically ill patients from mechanical ventilation
Indian Journal of Anaesthesia · 2026-11 · 70 (11) · 1211-1218
DOI: 10.4103/ija.ija_642_26 ↗Kurz gefasst
Fachartikel in der Zeitschrift Indian Journal of Anaesthesia, online erschienen am 20.11.2026. Verfasst von Eslam Sobhy Al Maghawry Mohamed und 2 weiteren Autor:innen. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Themen: Beatmung und Weaning
Abstract (Originalsprache)
Background and Aims: Deciding when to wean patients from mechanical ventilation is a vital decision in intensive care. This study aimed to investigate whether thoracic fluid content (TFC) could predict weaning outcome.
Methods
This prospective cohort study included patients mechanically ventilated for >48 h. TFC was measured 10 min prior to a spontaneous breathing trial (SBT) using electrical cardiometry. Weaning failure was defined as the need for invasive or non-invasive ventilatory support within 48 h post-extubation. TFC, the transmitral to mitral annular diastolic velocity ratio (E/e'), central venous pressure, inferior vena cava diameter, and 24-h fluid balance were assessed. Receiver operating characteristic analysis evaluated discriminatory performance, and multivariable logistic regression identified independent predictors of weaning failure.
Results
Eighty-nine patients were included; 35 (39.3%) experienced weaning failure. TFC was higher in patients with weaning failure than in those with successful weaning (median: 55 vs. 38 kΩ - ¹; P < 0.001). TFC demonstrated good discrimination [area under curve (AUC): 0.92; 95% confidence interval (CI): 0.86–0.97]. Using Youden’s index, the TFC cutoff was >46 kΩ - ¹, yielding 94.3% sensitivity and 79.6% specificity. E/e' demonstrated an AUC of 0.90 (95% CI: 0.84–0.96), with no significant difference from TFC ( P = 0.67). TFC (odds ratio: 1.24 per 1 kΩ - ¹ increase; 95% CI: 1.06–1.45; P = 0.008) and age were independently associated with weaning failure, whereas E/e' and other parameters were not.
Conclusion
TFC measured immediately before an SBT may serve as an adjunct for identifying patients at risk of unsuccessful weaning, with a threshold of >46 kΩ - ¹. Multi-centre external validation is warranted before clinical adoption.
Zitieren
APA
Mohamed, E. S. A. M., Mohamed, A. M. G., & Mohamed, M. G. (2026). The validity of thoracic fluid content measurement as a non-invasive predictor of weaning critically ill patients from mechanical ventilation. Indian Journal of Anaesthesia, 70(11), 1211-1218. https://doi.org/10.4103/ija.ija_642_26
Vancouver
Mohamed ESAM, Mohamed AMG, Mohamed MG. The validity of thoracic fluid content measurement as a non-invasive predictor of weaning critically ill patients from mechanical ventilation. Indian Journal of Anaesthesia. 2026;70(11):1211-1218. doi:10.4103/ija.ija_642_26
BibTeX
@article{Mohamed2026,
author = {Mohamed, Eslam Sobhy Al Maghawry and Mohamed, Abdalla Mohamed Goda and Mohamed, Mohamed Gaber},
title = {The validity of thoracic fluid content measurement as a non-invasive predictor of weaning critically ill patients from mechanical ventilation},
journal = {Indian Journal of Anaesthesia},
year = {2026},
volume = {70},
number = {11},
pages = {1211--1218},
doi = {10.4103/ija.ija_642_26}
}
EUVIMED