EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieOpen Access · CC BY-NC-ND 4.0

Comparison of first-attempt endoscope insertion success between LMA® Gastro™ and low-flow nasal cannula during upper gastrointestinal endoscopy: A prospective randomised controlled trial

Japhia Selvin iD, Stalin Vinayagam iD, Yaal Elango iD, Suman Lata iD, Pazhanivel Mohan iD

Indian Journal of Anaesthesia · 2026-03 · 70 (3) · 408-414

DOI: 10.4103/ija.ija_43_26 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Indian Journal of Anaesthesia, online erschienen am 13.03.2026. Verfasst von Japhia Selvin und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anaesthesiology and Critical Care, Jawaharlal Institute of Postgraduate Medical Education and Research (JIPMER), Puducherry, India. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Aims: Upper gastrointestinal (GI) endoscopic procedures under total intravenous anaesthesia (TIVA) pose risks of sedation-related complications. This study compared the first-attempt endoscope insertion success between the Laryngeal Mask Airway ® (LMA) Gastro™ and low-flow nasal cannula during upper GI endoscopy under TIVA.

Methods

This prospective randomised controlled study involved 140 adult patients scheduled for upper GI endoscopy under TIVA. The participants were randomly assigned into two groups: Group L (LMA ® Gastro™) and Group C (low-flow nasal cannula). In Group L, LMA ® Gastro™ was inserted, and in Group C, oxygen was supplemented using a low-flow nasal cannula at 4 litres/min. The primary outcome was first-attempt success of endoscope insertion. Secondary outcomes included endoscope insertion time, endoscopist and anaesthesiologist satisfaction scores, and intra- and postoperative complications. Data were analysed using statistical package for social sciences (SPSS) 19.0, and P < 0.05 was considered statistically significant.

Results

The first-attempt success rate for endoscope insertion was comparable between the groups (Group L: 92.6% vs. Group C: 95.7%, P = 0.44). However, the endoscopy insertion time was significantly prolonged in Group L (Median [interquartile range] (seconds): 30 [22-41] vs. 17.5 [13-22], P < 0.001). Anaesthesiologist satisfaction was comparable between the groups, but endoscopists were more satisfied with Group C ( P < 0.001). Group L had significantly fewer intraoperative respiratory adverse events compared with Group C; however, a higher incidence of postoperative sore throat was observed in Group L (20.5%).

Conclusion

The first-attempt endoscope insertion success rate was comparable between the LMA ® Gastro™ and nasal cannula groups in patients undergoing upper GI endoscopy under TIVA.

Schlagwörter

Stichwörter der Autor:innen

Airway managementanaesthesiaendoscopylaryngeal masks

Autor:innen und Institutionen

  • Department of Anaesthesiology and Critical Care, Jawaharlal Institute of Postgraduate Medical Education and Research (JIPMER), Puducherry, India.
  • Department of Medical Gastroenterology, Jawaharlal Institute of Postgraduate Medical Education and Research (JIPMER), Puducherry, India.

ORCID-Profile: Japhia Selvin, Stalin Vinayagam, Yaal Elango, Suman Lata, Pazhanivel Mohan

Zitieren

APA

Selvin, J., Vinayagam, S., Elango, Y., Lata, S., & Mohan, P. (2026). Comparison of first-attempt endoscope insertion success between LMA® Gastro™ and low-flow nasal cannula during upper gastrointestinal endoscopy: A prospective randomised controlled trial. Indian Journal of Anaesthesia, 70(3), 408-414. https://doi.org/10.4103/ija.ija_43_26

Vancouver

Selvin J, Vinayagam S, Elango Y, Lata S, Mohan P. Comparison of first-attempt endoscope insertion success between LMA® Gastro™ and low-flow nasal cannula during upper gastrointestinal endoscopy: A prospective randomised controlled trial. Indian Journal of Anaesthesia. 2026;70(3):408-414. doi:10.4103/ija.ija_43_26

BibTeX
@article{Selvin2026,
  author = {Selvin, Japhia and Vinayagam, Stalin and Elango, Yaal and Lata, Suman and Mohan, Pazhanivel},
  title = {Comparison of first-attempt endoscope insertion success between LMA® Gastro™ and low-flow nasal cannula during upper gastrointestinal endoscopy: A prospective randomised controlled trial},
  journal = {Indian Journal of Anaesthesia},
  year = {2026},
  volume = {70},
  number = {3},
  pages = {408--414},
  doi = {10.4103/ija.ija_43_26}
}
Kostenlos starten →