Erroneous Pulse Oximetry Readings and Local Cutaneous Variables: What We Should Know

Anuradha Bishnoi, Apoorva Sharma, Keshavamurthy Vinay, Ankur Jindal, Inderpaul Singh

Indian Dermatology Online Journal · 2025-07 · 16 (4) · 667-668

DOI: 10.4103/idoj.idoj_696_24 ↗

Kurz gefasst

Leserbrief in der Zeitschrift Indian Dermatology Online Journal, online erschienen am 10.02.2025. Verfasst von Anuradha Bishnoi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dermatology, Venereology and Leprology, Postgraduate Institute of Medical Education and Research, Chandigarh, India. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 5 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Dear Editor The widespread use of pulse oximeters during COVID-19 pandemic and the dependence on these devices for delegation of healthcare resources and constitution of guidelines for management of acute severe respiratory illness has raised intermittent concerns about their accuracy. A California-based physician recently sued the pulse oximeter manufacturers (12 companies) for overestimation of blood oxygen levels in people with skin of color, leading to adverse health outcomes.[1] This emphasizes the importance of discussing local variables related to skin or its appendages for correct interpretation of oximeter readings. The conventional fingertip pulse oximeters work on the principles of plethysmography (pulsatile signal produced by arterial blood) and spectrophotometry (distinct absorption spectra of different chromophores). Reduced hemoglobin HbH absorbs red light more, whereas oxygenated hemoglobin HbO2 absorbs infra-red light more and scatters red light, thus appearing bright red.[2] Two distinct light emitting diodes in one arm of the oximeter emit red and infra-red wavelengths (660 nm and 940 nm, respectively), which then travels through skin, nail plate, nail-bed, fat, and muscle to enter the arterial blood, where these wavelengths interact with HbH and HbO2. The photodetector in the other arm of the oximeter then measures the amount of light that is transmitted, reporting the relative proportions of HbH and HbO2. The absorption spectrum of melanin, an important chromophore present in pigmented skin, significantly overlaps with that of HbO2, resulting in overestimation of blood oxygen levels. Dermatologists who use lasers to treat vascular anomalies are aware of this overlap and its importance while selecting treatment parameters. Importantly, racial and ethnic differences resulting in erroneous pulse oximeter readings have been previously linked to increased incidence of occult/hidden hypoxemia in Asian, Black, and non-Black Hispanic COVID-19 patients, leading to omission or significant delays while deciding the eligibility for step-up COVID-19 therapies.[3] In a similar context, SpO2 values in fingers with white nail and yellow/brown nail onychomycosis patients measured significantly greater and lesser than the normal fingers, respectively, highlighting the role of nail thickness and discoloration.[4] In scleroderma, presence of skin fibrosis, sclerodactyly, loss of pulp, microvascular damage, digital ulcers, and altered pigmentation typically yielded false low or missing readings [Table 1].[5] Other dermatological conditions/parameters that could theoretically influence the readings by inducing inflammation and/or changes in thickness, pigmentation, and scaling on the nails and surrounding skin include psoriasis, eczema, lichen planus, lupus erythematosus, vasculitis, chilblains, mechanics hands of dermatomyositis, palmoplantar keratoderma, pachyonychia congenita, arsenical keratosis, morphea, pachydermodactyly, and use of nail varnishes/henna/colours/glitters/gels, and acrylic nails among various others.Table 1: Local cutaneous variables that can lead to erroneous readings of pulse oximetersAlternatives include using fingers clinically free of digital ulcers/sclerodactyly/onychomycosis, performing screening nail-fold capillaroscopy in the target finger, using ear,[5] esophageal, and forehead probes, and performing the gold standard, i.e. arterial blood gas analysis. To conclude, how common dermatoses affecting extremities and nails and skin physiology would affect oximetry readings should be further studied. Collaboration between technology and dermatology professionals could aid in the construction of more inclusive devices that take local cutaneous variables into account. Financial support and sponsorship Nil. Conflicts of interest There are no conflicts of interest.

Autor:innen und Institutionen

  • Department of Dermatology, Venereology and Leprology, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
  • Department of Pediatric Allergy, Immunology and Rheumatology, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
  • Department of Pulmonology, Postgraduate Institute of Medical Education and Research, Chandigarh, India.

Zitieren

APA

Bishnoi, A., Sharma, A., Vinay, K., Jindal, A., & Singh, I. (2025). Erroneous Pulse Oximetry Readings and Local Cutaneous Variables: What We Should Know. Indian Dermatology Online Journal, 16(4), 667-668. https://doi.org/10.4103/idoj.idoj_696_24

Vancouver

Bishnoi A, Sharma A, Vinay K, Jindal A, Singh I. Erroneous Pulse Oximetry Readings and Local Cutaneous Variables: What We Should Know. Indian Dermatology Online Journal. 2025;16(4):667-668. doi:10.4103/idoj.idoj_696_24

BibTeX
@article{Bishnoi2025,
  author = {Bishnoi, Anuradha and Sharma, Apoorva and Vinay, Keshavamurthy and Jindal, Ankur and Singh, Inderpaul},
  title = {Erroneous Pulse Oximetry Readings and Local Cutaneous Variables: What We Should Know},
  journal = {Indian Dermatology Online Journal},
  year = {2025},
  volume = {16},
  number = {4},
  pages = {667--668},
  doi = {10.4103/idoj.idoj_696_24}
}
Kostenlos starten →