Risk factors for stent dysfunction during long-term follow-up after EUS-guided biliary drainage using lumen-apposing metal stents: A prospective study
Endoscopic Ultrasound · 2023-03 · 12 (2) · 237-244
DOI: 10.4103/eus-d-22-00120 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopic Ultrasound, online erschienen am 03.03.2023. Verfasst von Sophie Geyl und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology, Limoges University Hospital, Limoges, France. Die Arbeit wurde bisher 32-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
EUS-guided choledoco-duodenostomy using electrocautery-enhanced lumen-apposing metal stents (ECE-LAMS) is becoming the gold standard in case of endoscopic retrograde cholangio-pancreatography failure for distal malignant obstruction. Long-term data in larger samples are lacking.
Methods
This was a prospective monocentric study including all patients who underwent EUS-guided choledochoduodenostomy (CDS) between September 2016 and December 2021. The primary endpoint was the rate of biliary obstruction during follow-up. Secondary endpoints were technical and clinical success rates, adverse event rates, and identification of risk factors for biliary obstruction.
Results
One hundred and twenty-three EUS-guided CDS using ECE-LAMS were performed at Limoges University Hospital were performed during the study period and included in the study. The main cause of obstruction was pancreatic adenocarcinoma in 91 (74.5%) cases. The technical and clinical success rates were 97.5% and 91%, respectively. Twenty patients (16.3%) suffered from biliary obstructions during a mean follow-up of 242 days. The clinical success rate for endoscopic desobstruction was 80% (16/20). In uni- and multivariate analyses, only the presence of a duodenal stent (odds ratio [OR]: 3.6, 95% confidence interval [CI] 95%: 1.2–10.2; P = 0.018) and a bile duct thinner than 15 mm (OR: 3.9, CI 95%: 1.3–11.7; P = 0.015) were the significant risk factors for biliary obstruction during the follow-up.
Conclusion
Obstruction of LAMS occurred in 16.3% of cases during follow-up and endoscopic desobstruction is efficacious in 80% of cases. The presence of duodenal stent and a bile duct thinner than 15 mm are the risk factors of obstruction. Except in these situation, EUS-CDS with ECE-LAMS could be proposed in the first intent in case of distal malignant obstruction.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Gastroenterology, Limoges University Hospital, Limoges, France.
- Department of Gastroenterology, Amiens University Hospital, Amiens, France.
- Department of Gastroenterology, Private Hospital Jean-Mermoz, Lyon, France.
Zitieren
APA
Geyl, S., Redelsperger, B., Yzet, C., Napoleon, B., Legros, R., Dahan, M., Lepetit, H., Ginestet, C., Jacques, J., & Albouys, J. (2023). Risk factors for stent dysfunction during long-term follow-up after EUS-guided biliary drainage using lumen-apposing metal stents: A prospective study. Endoscopic Ultrasound, 12(2), 237-244. https://doi.org/10.4103/eus-d-22-00120
Vancouver
Geyl S, Redelsperger B, Yzet C, Napoleon B, Legros R, Dahan M, et al. Risk factors for stent dysfunction during long-term follow-up after EUS-guided biliary drainage using lumen-apposing metal stents: A prospective study. Endoscopic Ultrasound. 2023;12(2):237-244. doi:10.4103/eus-d-22-00120
BibTeX
@article{Geyl2023,
author = {Geyl, Sophie and Redelsperger, Benjamin and Yzet, Clara and Napoleon, Bertrand and Legros, Romain and Dahan, Martin and Lepetit, Hugo and Ginestet, Claire and Jacques, Jérémie and Albouys, Jérémie},
title = {Risk factors for stent dysfunction during long-term follow-up after EUS-guided biliary drainage using lumen-apposing metal stents: A prospective study},
journal = {Endoscopic Ultrasound},
year = {2023},
volume = {12},
number = {2},
pages = {237--244},
doi = {10.4103/eus-d-22-00120}
}
EUVIMED