EUVIMEDEUVIMED entdecken
Crossref

Development and validation of a stability-indicating analytical method for simultaneous determination of sodium phenylbutyrate and taurursodiol in bulk and formulation using reverse phase ultra-performance liquid chromatography

Mahammad I. Beludari, Hari K. Chedela, Siva S.R. Lingareddy, China B. Dara, Shaik Karimulla

Egyptian Pharmaceutical Journal · 2024-04 · 23 (2) · 264-271

DOI: 10.4103/epj.epj_295_23 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Egyptian Pharmaceutical Journal, online erschienen am 27.02.2024. Verfasst von Mahammad I. Beludari und 4 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 13 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Amyotrophic Lateral Sclerosis, often known as Lou Gehrig’s disease, is typically treated with a combination therapy that includes both sodium phenylbutyrate (SPB) and taurursodiol (TRS).

Objectives

To assess both SPB and TRS in bulk and their dosage form concurrently, a stability-indicating analytical method was developed and validated using Ultra-Performance Liquid Chromatography. Patients and methods The chromatographic separation was carried out on a Waters C 18 Column, with dimensions of 150×4.6 mm i.d. and a particle size of 2 μm. A mobile phase consisting of a phosphate buffer pH 2.5 with methanol in the ratio of 45 : 65 v/v was, then delivered at a flow rate of 1 ml/min. Detection of the analytes occurred at 285 nm using a photo diode array detector. An auto sampler injected a 10 μl sample into the column, and the column was maintained at a temperature of 30°C. Results and conclusion SPB and TRS were eluted at 1.483 and 2.492 nm, respectively. Linearity was established in the range of 567–1701 μg/ml for SPB and 189–567 μg/ml for TRS. The robustness of the method was assessed by intentionally modifying parameters such as flow rate, detection wavelength, and column temperature. Furthermore, studies on forced degradation under various stress conditions, including acid, base, peroxide, heat, and ultra violet exposure, indicated the method’s capability to identify stable materials. In summary, the developed analytical approach for simultaneously determining SPB and TRS in bulk and their formulation was found to be specific, accurate, precise, and reliable.

Zitieren

APA

Beludari, M. I., Chedela, H. K., Lingareddy, S. S., Dara, C. B., & Karimulla, S. (2024). Development and validation of a stability-indicating analytical method for simultaneous determination of sodium phenylbutyrate and taurursodiol in bulk and formulation using reverse phase ultra-performance liquid chromatography. Egyptian Pharmaceutical Journal, 23(2), 264-271. https://doi.org/10.4103/epj.epj_295_23

Vancouver

Beludari MI, Chedela HK, Lingareddy SS, Dara CB, Karimulla S. Development and validation of a stability-indicating analytical method for simultaneous determination of sodium phenylbutyrate and taurursodiol in bulk and formulation using reverse phase ultra-performance liquid chromatography. Egyptian Pharmaceutical Journal. 2024;23(2):264-271. doi:10.4103/epj.epj_295_23

BibTeX
@article{Beludari2024,
  author = {Beludari, Mahammad I. and Chedela, Hari K. and Lingareddy, Siva S.R. and Dara, China B. and Karimulla, Shaik},
  title = {Development and validation of a stability-indicating analytical method for simultaneous determination of sodium phenylbutyrate and taurursodiol in bulk and formulation using reverse phase ultra-performance liquid chromatography},
  journal = {Egyptian Pharmaceutical Journal},
  year = {2024},
  volume = {23},
  number = {2},
  pages = {264--271},
  doi = {10.4103/epj.epj_295_23}
}