EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-SA 4.0

Comparative evaluation of biodentine, resin-modified glass ionomer cement, cention-N, and bulk-fill flowable composite on fracture resistance in endodontically treated teeth: An in vitro study

Parthasarathi Mondal, Utpal Halder, Kaushik Mistry, Snigdho Das, Kallol Kumar Saha, Debjyoti Karmakar

Endodontology · 2025-04 · 37 (2) · 212-216

DOI: 10.4103/endo.endo_247_24 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endodontology, online erschienen am 18.06.2025. Verfasst von Parthasarathi Mondal und 5 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

To assess the fracture resistance provided by four intraorifice barrier materials: biodentine (Septodont, Saint Maur des Fosses, France), resin-modified glass ionomer cement (RMGIC) (GC Gold label 2 LC Light Cured Universal Restorative, GC Products, Japan), cention-N (Ivoclar Vivadent, Schaan, Lichtenstein), and bulk-fill flowable composite (BFFC) (Shofu, Kyoto, Japan) in endodontically treated teeth.

Methods

An in vitro comparative study, with a sample size of 50 freshly extracted mandibular second premolars. The teeth were randomly assigned into four experimental groups ( n = 10 each) based on the type of intraorifice barrier applied: Group I (biodentine), Group II (RMGIC), Group III (cention-N), and Group IV (BFFC). A control group ( n = 10) was included with no intraorifice barrier. Universal testing equipment (Instron, USA) was used to apply a compressive load to each specimen to evaluate its fracture resistance.

Results

Group III exhibited the highest fracture resistance (906.27 ± 51.91 N), followed by Group IV (818.05 ± 57.93 N), Group I (684.73 ± 14.70 N), Group II (613.83 ± 59.30 N), and the control group (237.80 ± 18.87 N). Considerable differences were identified among the groups ( P < 0.0001).

Conclusion

Cention-N and BFFC provide superior fracture resistance compared to other tested materials.

Zitieren

APA

Mondal, P., Halder, U., Mistry, K., Das, S., Saha, K. K., & Karmakar, D. (2025). Comparative evaluation of biodentine, resin-modified glass ionomer cement, cention-N, and bulk-fill flowable composite on fracture resistance in endodontically treated teeth: An in vitro study. Endodontology, 37(2), 212-216. https://doi.org/10.4103/endo.endo_247_24

Vancouver

Mondal P, Halder U, Mistry K, Das S, Saha KK, Karmakar D. Comparative evaluation of biodentine, resin-modified glass ionomer cement, cention-N, and bulk-fill flowable composite on fracture resistance in endodontically treated teeth: An in vitro study. Endodontology. 2025;37(2):212-216. doi:10.4103/endo.endo_247_24

BibTeX
@article{Mondal2025,
  author = {Mondal, Parthasarathi and Halder, Utpal and Mistry, Kaushik and Das, Snigdho and Saha, Kallol Kumar and Karmakar, Debjyoti},
  title = {Comparative evaluation of biodentine, resin-modified glass ionomer cement, cention-N, and bulk-fill flowable composite on fracture resistance in endodontically treated teeth: An in vitro study},
  journal = {Endodontology},
  year = {2025},
  volume = {37},
  number = {2},
  pages = {212--216},
  doi = {10.4103/endo.endo_247_24}
}
Kostenlos starten →