Total keratometry versus simulated keratometry for intraocular lens power calculation in adult patients with traumatic aphakia and corneal scar
Journal of the Egyptian Ophthalmological Society · 2026-04 · 119 (2) · 142-149
DOI: 10.4103/ejos.ejos_68_25 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the Egyptian Ophthalmological Society, online erschienen am 13.04.2026. Verfasst von Ahmed M. Bahgat und 3 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
Traumatic aphakia with corneal scarring constitutes a major cause for vision loss following open globe injury. Accurate intraocular lens (IOL) power calculation is important to avoid postoperative refractive surprises making vision rehabilitation difficult.
Purpose
To compare the accuracy of total versus simulated keratometry for IOL power calculation in adult patients suffering from traumatic aphakia and corneal scarring following open globe injury repair. Patients and methods Patients were randomized into two groups: group A where IOL power was calculated using total keratometry and the Haigis formula and group B where IOL power was calculated using simulated keratometry and Haigis formula. Prediction error in both groups was assessed and compared at 1 and 3 months postoperatively. A secondary analysis was performed in group A to compare combinations of total keratometry with vergence formulas other than Haigis (Hoffer Q, Holladay 1, SRK-T) to the Haigis formula and to compare biometry of the sound eye with biometry of the injured eye.
Results
The study included 30 eyes in group A and 30 eyes in group B. Mean absolute prediction errors were significantly lower in group B than in group A at 1 month 1.24±0.81 D versus 2.28±1.67 D ( P =0.017) and at 3 months 1.19±0.83 D versus 2.27±1.72 D ( P =0.018). Group B contained significantly higher percentage of eyes within±1D (50 vs 20%) ( P =0.014) and within±2D (80 vs 50%) ( P =0.015). In group A, using the vergence formulas (Hoffer Q, Holladay 1, and SRK-T) did not improve prediction accuracy compared with the Haigis formula. Biometry of the sound eye was not significantly better than the injured eye and exhibited a wider range of prediction errors.
Conclusion
In patients with traumatic aphakia and corneal scarring, simulated keratometry by corneal topography gives more accurate refractive results for IOL power calculation than total keratometry. Biometry of the sound eye may provide a broader range of prediction errors than biometry of the injured eye.
Zitieren
APA
Bahgat, A. M., AbouSharkh, A. E., Zein, H. M., & Nasr, A. A. (2026). Total keratometry versus simulated keratometry for intraocular lens power calculation in adult patients with traumatic aphakia and corneal scar. Journal of the Egyptian Ophthalmological Society, 119(2), 142-149. https://doi.org/10.4103/ejos.ejos_68_25
Vancouver
Bahgat AM, AbouSharkh AE, Zein HM, Nasr AA. Total keratometry versus simulated keratometry for intraocular lens power calculation in adult patients with traumatic aphakia and corneal scar. Journal of the Egyptian Ophthalmological Society. 2026;119(2):142-149. doi:10.4103/ejos.ejos_68_25
BibTeX
@article{Bahgat2026,
author = {Bahgat, Ahmed M. and AbouSharkh, AbdulMonem E. and Zein, Hossam M. and Nasr, Abdallah A.},
title = {Total keratometry versus simulated keratometry for intraocular lens power calculation in adult patients with traumatic aphakia and corneal scar},
journal = {Journal of the Egyptian Ophthalmological Society},
year = {2026},
volume = {119},
number = {2},
pages = {142--149},
doi = {10.4103/ejos.ejos_68_25}
}
EUVIMED