Abstract (Originalsprache)

Purpose

The aim of this study was to evaluate the performance of the T2 formula compared to the Sanders, Retzlaff, Kraff theoretical (SRK/T) formula using different biometric parameters. Patients and methods This is an observational retrospective study that included 360 eyes of 360 patients. The eyes were classified into six subgroups. Three subgroups (each of 60 eyes) with an average axial length (AXL) of 22.0–24.5 mm: (a) eyes with flat keratometry (K) [44.0 D). The other three subgroups (each of 60 eyes) with average K readings of 42.0–44.0 D: (a) eyes with short AXL (26.0 mm). The Wang–Koch (WK) adjustment was applied to the AXL for the SRK/T formula in the eyes included in the very long AXL subgroup.

Results

For the whole included eyes, the mean absolute error was 0.42±0.43 and 0.32±0.43 D for the SRK/T and T2 formulas, respectively, with a statistically significant difference ( P =0.035). The flat K subgroup (44.0 D) showed a myopic mean error for both formulas of −0.41 and −0.06 D, respectively, with a statistically significant difference ( P =0.001). The short eyes subgroup (26.0 mm) showed a hyperopic mean error for both formulas of 0.38 and 0.27 D, respectively, with a statistically significant difference ( P =0.032). The WK adjustment was applied to the very long AXL subgroup by using the SRK/T formula. The mean prediction error was myopic (−0.24±0.13 D, from −0.60 to −0.02 D). The mean absolute error was 0.24±0.13 D (from 0.02 to 0.60 D).

Conclusion

Both the SRK/T and T2 formulas showed comparable outcomes in the eyes with average K readings and average or long AXL. The T2 formula showed better outcomes in the eyes with flat and steep K readings than the SRK/T formula. The T2 formula did not improve the SRK/T hyperopic outcome in the short and very long AXL eyes. For the very long AXL eyes, the SRK/T formula with the WK adjustment performed better than the T2 formula, with a desirable slightly myopic outcome.

Zitieren

APA

Helaly, H. A., Bardan, A. S., Ragab, A. M., & Ibrahim, T. M. (2026). Evaluation of the performance of the T2 formula versus the SRK/T formula along different biometric parameters. Delta Journal of Ophthalmology, 27(4), 260-266. https://doi.org/10.4103/djo.djo_4_26

Vancouver

Helaly HA, Bardan AS, Ragab AM, Ibrahim TM. Evaluation of the performance of the T2 formula versus the SRK/T formula along different biometric parameters. Delta Journal of Ophthalmology. 2026;27(4):260-266. doi:10.4103/djo.djo_4_26

BibTeX
@article{Helaly2026,
  author = {Helaly, Hany A. and Bardan, Ahmed S. and Ragab, Ahmed M. and Ibrahim, Tamer M.},
  title = {Evaluation of the performance of the T2 formula versus the SRK/T formula along different biometric parameters},
  journal = {Delta Journal of Ophthalmology},
  year = {2026},
  volume = {27},
  number = {4},
  pages = {260--266},
  doi = {10.4103/djo.djo_4_26}
}
Kostenlos starten →