Reusing operative supplies in cataract surgery: safety, cost reduction, and environmental sustainability in high-volume cataract practice
Delta Journal of Ophthalmology · 2026-10 · 27 (4) · 274-279
DOI: 10.4103/djo.djo_36_26 ↗Kurz gefasst
Fachartikel in der Zeitschrift Delta Journal of Ophthalmology, online erschienen am 19.11.2026. Verfasst von Mohammed Ezzeldawla und 4 weiteren Autor:innen. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Purpose
The aim of this study was to evaluate the safety of reusing operative supplies in cataract surgery and its effect on postoperative endophthalmitis, while also considering the environmental and economic implications of this practice. Patients and methods This prospective study included 10 000 consecutive cataract surgeries performed at the Military Hospital and at Elsafwa Eye Center, Sohag, Egypt, between January 2020 and January 2023. The patients were allocated into two clinical settings groups: a private group (4000 cases) and a charity group (6000 cases). The procedures were performed by a team of eight experienced cataract surgeons. All patients underwent phacoemulsification with foldable intraocular lens implantation, with extracapsular cataract extraction performed in selected cases or when intraoperative conversion was required. The reuse protocols involved selected operative supplies including gowns, phaco tips, cassettes, cartridges, ophthalmic viscosurgical devices, and pharmaceutical products, with sterilization and disinfection measures between the cases. Intracameral moxifloxacin prophylaxis was used in all cases. The primary outcome measure was documented postoperative endophthalmitis.
Results
No documented cases of postoperative endophthalmitis were reported. Posterior capsular rupture occurred in 124 (3.1%) private cases and 240 (4.0%) charity cases ( P =0.019). Conversion to extracapsular cataract extraction was required in 65 (1.6%) and 120 (2.0%) cases, respectively ( P =0.173). Corneal edema was reported in 286 (7.2%) and 450 (7.5%) cases, respectively ( P =0.511) and wound leak in three (0.08%) and six (0.10%) cases, respectively ( P =0.683). Toxic anterior segment syndrome was not documented in any case. The charity arm showed estimated reductions of 88.3% in the disposable material consumption, surgical waste generation, and procedural disposable cost compared with the private arm (all P
Zitieren
APA
Ezzeldawla, M., Zidane, M., Gamal, Y., Shandawily, S., & Anber, M. (2026). Reusing operative supplies in cataract surgery: safety, cost reduction, and environmental sustainability in high-volume cataract practice. Delta Journal of Ophthalmology, 27(4), 274-279. https://doi.org/10.4103/djo.djo_36_26
Vancouver
Ezzeldawla M, Zidane M, Gamal Y, Shandawily S, Anber M. Reusing operative supplies in cataract surgery: safety, cost reduction, and environmental sustainability in high-volume cataract practice. Delta Journal of Ophthalmology. 2026;27(4):274-279. doi:10.4103/djo.djo_36_26
BibTeX
@article{Ezzeldawla2026,
author = {Ezzeldawla, Mohammed and Zidane, Mervat and Gamal, Yasmine and Shandawily, Sara and Anber, Mohammed},
title = {Reusing operative supplies in cataract surgery: safety, cost reduction, and environmental sustainability in high-volume cataract practice},
journal = {Delta Journal of Ophthalmology},
year = {2026},
volume = {27},
number = {4},
pages = {274--279},
doi = {10.4103/djo.djo_36_26}
}
EUVIMED