Biomechanical Diffusion Modelling of Postoperative Ocular Kinematics: A Novel Framework for Comparing LASIK versus Small Incision Lenticule Extraction Visual Outcomes
Journal of Advanced Trends in Medical Research · 2025
DOI: 10.4103/atmr.atmr_130_25 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Advanced Trends in Medical Research, 2025. Verfasst von Saja Ahmed Alghamdi und 8 weiteren Autor:innen. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
Traditional assessments, such as refraction and wavefront aberrometry, do not capture the temporal fluctuations in visual performance following refractive surgery. To address this limitation, we propose a biomechanical diffusion model that integrates corneal biomechanics with ocular kinematics to evaluate dynamic postoperative outcomes in LASIK and small incision lenticule extraction (SMILE).
Methods
The framework combines high-frequency three-dimensional eye tracking (1000 Hz, infrared-based) with physics-informed diffusion modelling. Corneal stiffness parameters, derived from elasticity measures, were incorporated into stochastic differential equations, while corneal topography maps (25,000 elevation points) were processed through a graph neural network to generate surgical context embeddings that modulate diffusion dynamics. Dynamic refractive error and saccadic precision were extracted within biomechanical constraints. A cohort of 120 myopic patients (60 LASIK, 60 SMILE; spherical equivalent −1.00D to −8.00D) underwent standardised visual tasks with eye-tracking, and clinical refraction was assessed at 1 week, 1 month and 3 months postoperatively.
Results
SMILE demonstrated faster kinematic stabilisation (28.2 ± 3.1 days vs. LASIK: 35.7 ± 4.2 days; P = 0.05), higher saccadic accuracy at 1 month (0.91 ± 0.04 vs. 0.86 ± 0.11) and lower trajectory prediction error (RMSE: 0.39 ± 0.09 vs. 0.48 ± 0.11). Simulated refractive outcomes correlated strongly with clinical measures, including contrast sensitivity (SMILE: r = 0.76 ± 0.07; LASIK: r = 0.71 ± 0.08) and patient-reported visual quality (SMILE: r = 0.72 ± 0.09; LASIK: r = 0.68 ± 0.10).
Conclusion
SMILE achieved earlier stabilisation and superior kinematic precision compared with LASIK, reflecting distinct biomechanical effects of lenticule removal versus flap creation. The proposed model provides a novel framework for dynamic assessment of refractive surgery outcomes, with potential applications in personalised surgical planning and long-term visual quality prediction.
Zitieren
APA
Alghamdi, S. A., Asiri, A. I. A. A., Al-Nasser, M. Y., Habib, K. T., Alghamdi, A. D. M., Alzahrani, G. F., Alzahrani, G. M., Aliwi, R. A. A., & Morfeq, H. A. (2025). Biomechanical Diffusion Modelling of Postoperative Ocular Kinematics: A Novel Framework for Comparing LASIK versus Small Incision Lenticule Extraction Visual Outcomes. Journal of Advanced Trends in Medical Research. https://doi.org/10.4103/atmr.atmr_130_25
Vancouver
Alghamdi SA, Asiri AIAA, Al-Nasser MY, Habib KT, Alghamdi ADM, Alzahrani GF, et al. Biomechanical Diffusion Modelling of Postoperative Ocular Kinematics: A Novel Framework for Comparing LASIK versus Small Incision Lenticule Extraction Visual Outcomes. Journal of Advanced Trends in Medical Research. 2025. doi:10.4103/atmr.atmr_130_25
BibTeX
@article{Alghamdi2025,
author = {Alghamdi, Saja Ahmed and Asiri, Abdulrahim Ibrahim Ali AlMoawadh and Al-Nasser, Mohammed Youssif and Habib, Khadija Tariq and Alghamdi, Abdullah Dawood Mohammed and Alzahrani, Ghala Fahad and Alzahrani, Ghala Mohammed and Aliwi, Rakan Abdulaziz Al and Morfeq, Hussein Ali},
title = {Biomechanical Diffusion Modelling of Postoperative Ocular Kinematics: A Novel Framework for Comparing LASIK versus Small Incision Lenticule Extraction Visual Outcomes},
journal = {Journal of Advanced Trends in Medical Research},
year = {2025},
doi = {10.4103/atmr.atmr_130_25}
}
EUVIMED