Real-time Electromechanical Mapping and Dosage Optimisation for Botox–Occlusal Appliance Combination Therapy in Bruxism
Journal of Advanced Trends in Medical Research · 2025
DOI: 10.4103/atmr.atmr_102_25 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Advanced Trends in Medical Research, 2025. Verfasst von Lana Saad Saeed Aldooh und 8 weiteren Autor:innen. Die Arbeit nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
Bruxism treatment relies on occlusal appliances and Botox. The current methods often lack real-time personalisation, with static splints and empirical dosing leading to inconsistent therapeutic outcomes.
Objective
To develop a real-time electromechanical mapping and therapy optimisation system that integrates high-density electromyography (HD-EMG) and ultrafast ultrasound imaging (UUI) to personalise Botox dosage and occlusal appliance design for bruxism management.
Methods
The system generates activation–strain maps to identify hyperactive muscles. Botox dosage is tailored using activation energy metrics and pharmacokinetic modelling. UUI-derived jaw kinematics guide splint design via FEA and reinforcement learning. A robotic injector operates in a closed loop with HD-EMG and UUI feedback. Graphene electrodes and phased-array ultrasound enhance signal fidelity. A graph neural network optimises dosage.
Results
Compared to conventional treatments, the proposed system reduced bruxism episodes by 58%, increased masseter thickness reduction by 2.4 × and improved injection accuracy from 2.3 mm to 0.51 mm. The dynamic occlusal splint design also lowered peak bite forces by 38%, while ensuring consistent contact distribution. Patients reported higher satisfaction and reduced pain levels. Longitudinal adaptation further enhanced efficacy with a 42% greater reduction in focal hyperactivity.
Conclusion
This framework merges electrophysiological mapping, biomechanical modelling and intelligent control to deliver personalised bruxism therapy. By unifying Botox and appliance optimisation into a closed-loop system, it addresses limitations of existing treatments and offers a new paradigm in neuromuscular intervention.
Zitieren
APA
Aldooh, L. S. S., Alqahtani, S. J., Alghamdi, R. M., Ali, A. B., Alqahtani, A. A., Arim, A. M. S., Alshareif, L. S., Malwi, R. A., & Alyahya, K. A. (2025). Real-time Electromechanical Mapping and Dosage Optimisation for Botox–Occlusal Appliance Combination Therapy in Bruxism. Journal of Advanced Trends in Medical Research. https://doi.org/10.4103/atmr.atmr_102_25
Vancouver
Aldooh LSS, Alqahtani SJ, Alghamdi RM, Ali AB, Alqahtani AA, Arim AMS, et al. Real-time Electromechanical Mapping and Dosage Optimisation for Botox–Occlusal Appliance Combination Therapy in Bruxism. Journal of Advanced Trends in Medical Research. 2025. doi:10.4103/atmr.atmr_102_25
BibTeX
@article{Aldooh2025,
author = {Aldooh, Lana Saad Saeed and Alqahtani, Sara Jubran and Alghamdi, Raghad Mosfer and Ali, Almaha Ben and Alqahtani, Amwaj Awn and Arim, Alanoud Morayah Saeed and Alshareif, Lujain Sultan and Malwi, Reema Abdullah and Alyahya, Khalid Abdultaif},
title = {Real-time Electromechanical Mapping and Dosage Optimisation for Botox–Occlusal Appliance Combination Therapy in Bruxism},
journal = {Journal of Advanced Trends in Medical Research},
year = {2025},
doi = {10.4103/atmr.atmr_102_25}
}
EUVIMED