EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Cardiac output measurement in Fontan circulation: Challenges and potential emerging solutions

Ashish H Shah, Veena Bharathi Kota, Sivasubramanian Ramakrishnan

Annals of Pediatric Cardiology · 2026-03 · 19 (2) · 188-192

DOI: 10.4103/apc.apc_376_25 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Pediatric Cardiology, online erschienen am 25.05.2026. Verfasst von Ashish H Shah und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine, Section of Cardiology, University of Manitoba, Winnipeg, MB, Canada. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Similar to other cardiovascular conditions, accurate cardiac output (CO) assessment in Fontan patients is critical for evaluation of hemodynamic state. However, traditional methodologies, including the Fick principle, thermodilution, Doppler echocardiography, and cardiac magnetic resonance imaging face substantial limitations due to Fontan-specific anatomy and physiology. Impedance cardiography-based technologies offer a noninvasive alternative, yet they remain undervalidated in this unique population. This review highlights the challenges of established methods and emphasizes the need to explore, refine, and validate impedance cardiography-based CO monitoring across pediatric and adult Fontan patients.

Schlagwörter

Stichwörter der Autor:innen

Cardiac outputFontan circulationchallengesemerging technologiesmethods

Autor:innen und Institutionen

  • Department of Internal Medicine, Section of Cardiology, University of Manitoba, Winnipeg, MB, Canada.
  • Department of Cardiology, All India Institute of Medical Sciences, New Delhi, India.

Zitieren

APA

Shah, A. H., Kota, V. B., & Ramakrishnan, S. (2026). Cardiac output measurement in Fontan circulation: Challenges and potential emerging solutions. Annals of Pediatric Cardiology, 19(2), 188-192. https://doi.org/10.4103/apc.apc_376_25

Vancouver

Shah AH, Kota VB, Ramakrishnan S. Cardiac output measurement in Fontan circulation: Challenges and potential emerging solutions. Annals of Pediatric Cardiology. 2026;19(2):188-192. doi:10.4103/apc.apc_376_25

BibTeX
@article{Shah2026,
  author = {Shah, Ashish H and Kota, Veena Bharathi and Ramakrishnan, Sivasubramanian},
  title = {Cardiac output measurement in Fontan circulation: Challenges and potential emerging solutions},
  journal = {Annals of Pediatric Cardiology},
  year = {2026},
  volume = {19},
  number = {2},
  pages = {188--192},
  doi = {10.4103/apc.apc_376_25}
}
Kostenlos starten →