EUVIMEDEUVIMED entdecken
Open Access

Comparative study of quality of leukoreduced packed red blood cell units as assessed by nageotte hemocytometry and flow cytometry

Mohd Anas Sheikh, Amit Kumar Biswas, Ajay Kumar Baranwal, Neerja Kushwaha, Santosh Karade, Joseph Philip

Asian Journal of Transfusion Science · 2023-01 · 17 (1) · 63-68

DOI: 10.4103/ajts.ajts_101_21 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Asian Journal of Transfusion Science, 2023-01. Verfasst von Mohd Anas Sheikh und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Immunohematology and Blood Transfusion, Armed Forces Medical College, Pune, Maharashtra, India. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Assessment of residual white blood cell (rWBC) count is vital to ascertain the quality of leukodepleted (LD) blood components. Automated cell analyzers lack the sensitivity for the assessment of very few leukocytes as found in LD blood components. Flow Cytometry (FC) based methods and Nageotte hemocytometer are the most commonly used techniques for this purpose. The objective of this study was to compare the use of Nageotte hemocytometer and FC for quality control of LD red blood cell units. MATERIALS AND METHODS: A prospective, observational study was conducted in the Department of Immunohematology and Blood Transfusion of a tertiary care center from September 2018 to September 2020. About 303 LD-packed red blood cell units were tested by FC and Nageotte hemocytometer for rWBCs. RESULTS: The number of rWBC (mean) detected by flow cytometer and Nageotte's hemocytometer was 1.06 ± 0.43 white blood cell (WBC)/μL and 0.67 ± 0.39 WBC/μL, respectively. Coefficient of variation was 58.37% by Nageotte hemocytometer method and 40.46% by FC. Linear regression analysis did not show any correlation (R 2 = 0.098, P = 0.001) whereas Pearson's correlation coefficient showed a weak relation (r = 0.31) between the two methods. CONCLUSION: Flow cytometric technique provides a more precise and accurate objective tool compared to Nageotte hemocytometer which is labor intensive, time consuming, and prone to errors arising out of subjectivity along with reported underestimation bias. In the absence of adequate infrastructure, resources, and trained workforce, Nageotte hemocytometer method is a reliable alternative. Nageotte's chamber could be best used in the resource-constrained setup as it offers a relatively inexpensive, simple, and viable means to enumerate rWBCs.

Schlagwörter

Stichwörter der Autor:innen

Alloimmunizationflow cytometryleukodepletionnageotte hemocytometerquality controlresidual white blood cell count

Autor:innen und Institutionen

  • Department of Immunohematology and Blood Transfusion, Armed Forces Medical College, Pune, Maharashtra, India.
  • Department of Immunohematology and Blood Transfusion, CH(CC), Lucknow, Uttar Pradesh, India.
  • Department of Microbiology, Armed Forces Medical College, Pune, Maharashtra, India.
  • Department of Transfusion Medicine, Bharati Vidyapeeth University, Pune, Maharashtra, India.

Zitieren

APA

Sheikh, M. A., Biswas, A. K., Baranwal, A. K., Kushwaha, N., Karade, S., & Philip, J. (2023). Comparative study of quality of leukoreduced packed red blood cell units as assessed by nageotte hemocytometry and flow cytometry. Asian Journal of Transfusion Science, 17(1), 63-68. https://doi.org/10.4103/ajts.ajts_101_21

Vancouver

Sheikh MA, Biswas AK, Baranwal AK, Kushwaha N, Karade S, Philip J. Comparative study of quality of leukoreduced packed red blood cell units as assessed by nageotte hemocytometry and flow cytometry. Asian Journal of Transfusion Science. 2023;17(1):63-68. doi:10.4103/ajts.ajts_101_21

BibTeX
@article{Sheikh2023,
  author = {Sheikh, Mohd Anas and Biswas, Amit Kumar and Baranwal, Ajay Kumar and Kushwaha, Neerja and Karade, Santosh and Philip, Joseph},
  title = {Comparative study of quality of leukoreduced packed red blood cell units as assessed by nageotte hemocytometry and flow cytometry},
  journal = {Asian Journal of Transfusion Science},
  year = {2023},
  volume = {17},
  number = {1},
  pages = {63--68},
  doi = {10.4103/ajts.ajts_101_21}
}