Accuracy of Intraoperative Transesophageal Echocardiographic Doppler Parameters in Assessing the Right Ventricular Diastolic Function After Repair of Tetralogy of Fallot in Pediatric Patients
Annals of Cardiac Anaesthesia · 2025
DOI: 10.4103/aca.aca_85_24 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Annals of Cardiac Anaesthesia, 2025. Verfasst von Nagarjuna Panidapu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac Anaesthesia, Amrita Institute of Medical Sciences, Kochi, Kerala, India. Hauptthemen laut MEDLINE: Tetralogy of Fallot, Echocardiography, Transesophageal, Echocardiography, Doppler, Monitoring, Intraoperative. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).
Abstract (Originalsprache)
Background
This study aimed to assess the accuracy of tricuspid spectral Doppler (E/A) and tissue Doppler parameters (E/E’) to diagnose right ventricular diastolic dysfunction (RVDD) in comparison to American Society of Echocardiography (ASE criteria) in pediatric tetralogy of Fallot (TOF) patients after surgical repair.
Methods
This prospective, observational study was done at a tertiary care hospital involving 40 pediatric TOF patients aged less than 2 years who underwent complete intracardiac repair with cardiopulmonary bypass (CPB). Echocardiographic observations were made using a pediatric transesophageal echocardiography probe after surgical repair in the post-CPB period. The ASE-described parameters (late diastolic forward flow in the main pulmonary artery, right atrial dilatation, inferior vena cava dilatation, and hepatic venous flow reversal) were acquired to diagnose the RVDD. The tricuspid Doppler parameters (E/A and E/E’) were measured, and its predictive ability to diagnose RVDD was analyzed and compared with the ASE criteria.
Results
Based on the ASE criteria, 13 patients (32.5%) were diagnosed to have RVDD. We found that an E/E’ ratio of ≥ 6.26 and an E/A ratio of >1.34 can be taken as the cutoff for diagnosing the RVDD. Based on the tricuspid Doppler parameters (E/A > 1.34 and E/E’ >6.26), 17 patients (42.5%) were diagnosed to have RVDD, which was comparable to that of the diagnosis by ASE criteria ( P > 0.05).
Conclusion
The results suggested that the use of tricuspid Doppler parameters can be equally accurate and reproducible to the current ASE-described echocardiographic parameters for diagnosing RVDD after surgical repair of TOF.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Cardiac Anaesthesia, Amrita Institute of Medical Sciences, Kochi, Kerala, India.
- Department of Cardiothoracic and Vascular Anaesthesia, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Trivandrum, Kerala, India.
- Department of Cardiovascular and Thoracic Surgery, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Trivandrum, Kerala, India.
Zitieren
APA
Panidapu, N., Babu, S., Dharan, B. S., Sen, B., & Koshy, T. (2025). Accuracy of Intraoperative Transesophageal Echocardiographic Doppler Parameters in Assessing the Right Ventricular Diastolic Function After Repair of Tetralogy of Fallot in Pediatric Patients. Annals of Cardiac Anaesthesia. https://doi.org/10.4103/aca.aca_85_24
Vancouver
Panidapu N, Babu S, Dharan BS, Sen B, Koshy T. Accuracy of Intraoperative Transesophageal Echocardiographic Doppler Parameters in Assessing the Right Ventricular Diastolic Function After Repair of Tetralogy of Fallot in Pediatric Patients. Annals of Cardiac Anaesthesia. 2025. doi:10.4103/aca.aca_85_24
BibTeX
@article{Panidapu2025,
author = {Panidapu, Nagarjuna and Babu, Saravana and Dharan, Baiju S and Sen, Barsha and Koshy, Thomas},
title = {Accuracy of Intraoperative Transesophageal Echocardiographic Doppler Parameters in Assessing the Right Ventricular Diastolic Function After Repair of Tetralogy of Fallot in Pediatric Patients},
journal = {Annals of Cardiac Anaesthesia},
year = {2025},
doi = {10.4103/aca.aca_85_24}
}
EUVIMED