Palpation versus Ultrasound-Guided Dynamic Needle Tip Positioning Technique for Radial Artery Cannulation
Annals of Cardiac Anaesthesia · 2025
DOI: 10.4103/aca.aca_209_24 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Annals of Cardiac Anaesthesia, 2025. Verfasst von Sujan Dhakal und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anaesthesiology and Critical Care, Provincial Hospital Bhadrapur (PHB), Nepal. Hauptthemen laut MEDLINE: Radial Artery, Palpation, Catheterization, Peripheral, Ultrasonography, Interventional. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).
Abstract (Originalsprache)
Introduction
Invasive blood pressure monitoring is the clinical reference during perioperative patient management. It is usually performed by cannulating the radial artery. Different clinical conditions make arterial cannulation difficult using the conventional palpation (CP) method. This study compares the ultrasonography (USG)-guided dynamic needle tip positioning (DNTP) technique with the CP method to assess the first-pass success rate of radial artery cannulation.
Methods
In the operation theater of a university hospital, a total of 52 adult patients requiring arterial cannulation were randomized into two equal groups. Arterial cannulation was performed using the CP method in one group and the ultrasound-guided DNTP method in the other group. The first-pass success rate was the primary objective. The 5-minute success rate, the time required for successful cannulation, the number of skin punctures, and the number of cannulae used were also compared using the Chi-square test, an independent sample t-test, and the Mann–Whitney U test.
Results
The first-pass success rate was significantly higher in the USG-guided DNTP method (88.5%) compared to the CP method (46.2%) ( P 0.001). The overall 5-minute success rate was 96.2% in the USG-guided DNTP and 65.4% ( P 0.005) in the CP method. The median time for successful cannulation was significantly lesser in the USG-guided DNTP group [44 s (IQR: 35–72)] compared to the CP group [134 s (IQR: 28–378)] ( P 0.007). The mean number of skin punctures in the USG-guided DNTP group was 1.15 ± 0.46 and 2.04 ± 1.18 in the CP group ( P 0.001).
Conclusion
USG-guided DNTP method of radial artery cannulation increased the first-pass success rate.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anaesthesiology and Critical Care, Provincial Hospital Bhadrapur (PHB), Nepal.
- Department of Anaesthesiology, Institute of Medicine (IOM), Tribhuvan University Teaching Hospital(TUTH), Nepal.
- Department of Cardiothoracic and Vascular Anaesthesiology, Manmohan Cardiothoracic Vascular and Transplant Center, Institute of Medicine (IOM), Tribhuvan University, Nepal.
- Department of Critical Care Medicine, Institute of Medicine (IOM), Tribhuvan University Teaching Hospital(TUTH), Nepal.
- Department of Obstetrics and Gynaecology, Provincial Hospital Bhadrapur (PHB), Nepal.
- Department of Epidemiology and Preventive Medicine, Monash University, Melbourne, VIC, Australia.
Zitieren
APA
Dhakal, S., Shrestha, G. S., Lamsal, R., Bastola, P., Gautam, E., & Shrestha, A. (2025). Palpation versus Ultrasound-Guided Dynamic Needle Tip Positioning Technique for Radial Artery Cannulation. Annals of Cardiac Anaesthesia. https://doi.org/10.4103/aca.aca_209_24
Vancouver
Dhakal S, Shrestha GS, Lamsal R, Bastola P, Gautam E, Shrestha A. Palpation versus Ultrasound-Guided Dynamic Needle Tip Positioning Technique for Radial Artery Cannulation. Annals of Cardiac Anaesthesia. 2025. doi:10.4103/aca.aca_209_24