EUVIMEDEUVIMED entdecken
FallberichtOpen Access

Maintaining a Bloodless Field for HeartMate 3 Placement: Splicing an RVAD Outflow Cannula into the CPB Venous Reservoir for Complete LV Emptying

Justin W Walker, S Michael Roberts

Annals of Cardiac Anaesthesia · 2024

DOI: 10.4103/aca.aca_18_24 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Annals of Cardiac Anaesthesia, 2024. Verfasst von Justin W Walker und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Perioperative Medicine, Penn State Milton S. Hershey Medical Center, Hershey, Pennsylvania, USA. Hauptthemen laut MEDLINE: Heart-Assist Devices, Cardiopulmonary Bypass. Die Arbeit nennt 9 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Over the previous 20 years, the use of extracorporeal membranous oxygenation (ECMO) as a bridge to durable left ventricular assist device (dLVAD) increased significantly. Additionally, emerging literature has demonstrated a protective effect of biventricular decompression while on ECMO, with one such strategy including a temporary LVAD and right ventricular assist device (RVAD). The complexity of these operations is increased by the frequency of re-sternotomies, which result in adhesions and difficult access to traditional cannulation sites. In this case report, we present a patient presenting for a re-sternotomy for dLVAD on biventricular support in whom the RVAD outflow cannula was spliced into the cardiopulmonary bypass venous reservoir by the cardiac anesthesiologist. This innovative cannulation strategy allowed for continuation of RVAD flows to prevent thrombosis and active venting of the pulmonary artery to facilitate a bloodless surgical field.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart-Assist DevicesCardiopulmonary BypassHumansMaleExtracorporeal Membrane OxygenationCannulaBloodless Medical and Surgical ProceduresMiddle Aged

Autor:innen und Institutionen

  • Department of Anesthesiology and Perioperative Medicine, Penn State Milton S. Hershey Medical Center, Hershey, Pennsylvania, USA.

Zitieren

APA

Walker, J. W., & Roberts, S. M. (2024). Maintaining a Bloodless Field for HeartMate 3 Placement: Splicing an RVAD Outflow Cannula into the CPB Venous Reservoir for Complete LV Emptying. Annals of Cardiac Anaesthesia. https://doi.org/10.4103/aca.aca_18_24

Vancouver

Walker JW, Roberts SM. Maintaining a Bloodless Field for HeartMate 3 Placement: Splicing an RVAD Outflow Cannula into the CPB Venous Reservoir for Complete LV Emptying. Annals of Cardiac Anaesthesia. 2024. doi:10.4103/aca.aca_18_24

BibTeX
@article{Walker2024,
  author = {Walker, Justin W and Roberts, S Michael},
  title = {Maintaining a Bloodless Field for HeartMate 3 Placement: Splicing an RVAD Outflow Cannula into the CPB Venous Reservoir for Complete LV Emptying},
  journal = {Annals of Cardiac Anaesthesia},
  year = {2024},
  doi = {10.4103/aca.aca_18_24}
}
Kostenlos starten →