Fachartikel in der Zeitschrift Advanced Biomedical Research, 2024-01. Verfasst von Azim Honarmand und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Anesthesiology and Critical Care Research Center, Isfahan University of Medical Sciences, Isfahan, Iran. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
The present study aimed at comparing the hemodynamic responses to laryngoscopy and initiation of intubation with either direct or video-assisted laryngoscopy. Materials and Methods: This double-blind clinical trial was performed on 90 pregnant women candidates for cesarean section under general anesthesia. The participants were divided into two groups. In the first group, intubation was performed using direct Macintosh laryngoscope (MCL group). The second group underwent intubation using the GlideScope video laryngoscope (GSL group). Then, systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), heart rate (HR), the percentage of the saturation of peripheral oxygen (SpO2), the time-to-intubation (TTI), and the number of intubation attempts were recorded.
Results
SBP, DBP, and MAP in the MCL group were significantly higher than GSL group 1, 3, and 5 min after laryngoscopy ( P < 0.05). HR in the MCL group with the mean of 118.44 ± 15.53 bpm was significantly higher than that the GSL group with the mean of 110.11 ± 16.68 bpm only 3 min after laryngoscopy ( P = 0.016). The TTI in the MCL group was significantly longer than that of the GSL group (12.80 ± 1.86 vs. 10.15 ± 2.61; P = 0.001). The frequency of the first intubation attempt in the GSL group with 91.1% was significantly higher than that the MCL group with 84.4% ( P = 0.003).
Conclusion
It seems that the GSL technique is a better choice to conduct laryngoscopy with more success in intubation and a higher stability of the patients’ hemodynamic status.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anesthesiology, Anesthesiology and Critical Care Research Center, Isfahan University of Medical Sciences, Isfahan, Iran.
- Department of Obstetrics and Gynecology, Shahrekord University of Medical Sciences, Shahrekord, Iran.
- Department of Anesthesiology, Isfahan University of Medical Sciences, Isfahan, Iran.
Zitieren
APA
Honarmand, A., Ebrahim Babaei, M., Jafari, M., & Safavi, M. R. (2024). Comparative Evaluation of Direct Laryngoscopy Versus GlideScope for the Purpose of Laryngoscopy Management and Intubation in Candidates of Cesarean Delivery with General Anesthesia. Advanced Biomedical Research, 13. https://doi.org/10.4103/abr.abr_308_21
Vancouver
Honarmand A, Ebrahim Babaei M, Jafari M, Safavi MR. Comparative Evaluation of Direct Laryngoscopy Versus GlideScope for the Purpose of Laryngoscopy Management and Intubation in Candidates of Cesarean Delivery with General Anesthesia. Advanced Biomedical Research. 2024;13. doi:10.4103/abr.abr_308_21
BibTeX
@article{Honarmand2024,
author = {Honarmand, Azim and Ebrahim Babaei, Mahtab and Jafari, Mohammad and Safavi, Mohammad Reza},
title = {Comparative Evaluation of Direct Laryngoscopy Versus GlideScope for the Purpose of Laryngoscopy Management and Intubation in Candidates of Cesarean Delivery with General Anesthesia},
journal = {Advanced Biomedical Research},
year = {2024},
volume = {13},
doi = {10.4103/abr.abr_308_21}
}
EUVIMED