In vitro Assessment of Fit Accuracy of Removable Partial Denture Frameworks Fabricated by Milling, Selective Laser Melting, and Conventional Methods
Annals of African Medicine · 01.07.2026
DOI: 10.4103/aam.aam_408_26 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of African Medicine, online erschienen am 01.07.2026. Verfasst von Vaibhav Awinashe. Beteiligte Einrichtung: Department of Prosthetic Dental Sciences, College of Dentistry, Qassim University, Buraydah, Saudi Arabia.
Abstract (Originalsprache)
Introduction
In many clinical situations, removable partial denture (RPD) frameworks are used when bone and tissue support are lost. This research was done to estimate the fit accuracy of RPD frameworks created by Milling technique, selective laser melting (SLM), and the traditional means using gypsum models. Materials and Methods: A total of 30 partially edentulous casts with Kennedy class-I level were separated into three groups of 10 samples each. The RPD structures of Group I were produced with the use of chromium–cobalt in the cooling slope (CS) casting technique; Group II with the use of chromium–cobalt in the SLM method; and Group III with the use of polyether ether ketone (PEEK) in the milling system. Gypsum models were made by filling the frames constructed with polyvinyl siloxane and weighing the rubber laminas. The data obtained was evaluated statistically.
Results
The biggest gap was observed between the group of SLM structures and the group of CS frameworks. The group of Milling frameworks having the better accuracy for the gypsum models.
Conclusions
The structures of the RPD structures created with PEEK by means of the milling technique had the highest accuracy of fit on the gypsum models, in contrast to the Cr-Co structures fabricated with the two methods, where the exactness depended on the fabricating method.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Prosthetic Dental Sciences, College of Dentistry, Qassim University, Buraydah, Saudi Arabia.
Zitieren
APA
Awinashe, V. (2026). In vitro Assessment of Fit Accuracy of Removable Partial Denture Frameworks Fabricated by Milling, Selective Laser Melting, and Conventional Methods. Annals of African Medicine. https://doi.org/10.4103/aam.aam_408_26
Vancouver
Awinashe V. In vitro Assessment of Fit Accuracy of Removable Partial Denture Frameworks Fabricated by Milling, Selective Laser Melting, and Conventional Methods. Annals of African Medicine. 2026. doi:10.4103/aam.aam_408_26
BibTeX
@article{Awinashe2026,
author = {Awinashe, Vaibhav},
title = {In vitro Assessment of Fit Accuracy of Removable Partial Denture Frameworks Fabricated by Milling, Selective Laser Melting, and Conventional Methods},
journal = {Annals of African Medicine},
year = {2026},
doi = {10.4103/aam.aam_408_26}
}
EUVIMED