Investigating the Magnetic Resonance Imaging Cross-sectional Area That Best Correlates with Intraoperative Hamstring Autograft Size
Annals of African Medicine · 2026
DOI: 10.4103/aam.aam_304_25 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Annals of African Medicine, 2026. Verfasst von Govind Kumar Gupta und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Rajendra Institute of Medical Sciences, Ranchi, Jharkhand, India. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Hamstring Tendons, Autografts, Anterior Cruciate Ligament Reconstruction. Die Arbeit nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
Hamstring tendon autografts are widely used for anterior cruciate ligament (ACL) reconstruction, but preoperative prediction of graft diameter remains a clinical challenge. Magnetic resonance imaging (MRI)-based cross-sectional area (CSA) measurements are increasingly being used to estimate graft adequacy.
Objective
To determine which MRI-based CSA measurement level most accurately correlates with intraoperative hamstring autograft diameter in ACL reconstruction. Methodology: A prospective observational study was conducted on 41 patients aged 20–45 years undergoing ACL reconstruction. MRI CSA of the semitendinosus and gracilis tendons was measured at two anatomical levels: anteroposterior (AP) and joint line. Correlation with intraoperative graft size was assessed using Pearson and Spearman coefficients. MRI data were analyzed using Horos, and statistical analysis was performed in JASP software.
Results
The mean CSA at the AP level (19.63 mm²) was higher than at the joint line (16.55 mm²). The AP CSA showed the strongest correlation with intraoperative graft diameter ( r = 0.858, P < 0.001), followed by joint line CSA ( r = 0.625). The average intraoperative graft diameter was 8.48 mm.
Conclusion
MRI-based CSA measurement at the AP level has proven to be a reliable, noninvasive predictor of intraoperative hamstring graft diameter, aiding in surgical planning and graft sufficiency prediction.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedics, Rajendra Institute of Medical Sciences, Ranchi, Jharkhand, India.
- Department of Anatomy, Sheikh Bhikhari Medical College, Hazaribagh, Jharkhand, India.
- Department of Orthopaedics, Mahatma Gandhi Memorial Medical College, Jamshedpur, Jharkhand, India.
Zitieren
APA
Gupta, G. K., Das, A. K., Prabhat, V., Rani, S., & Chakraborty, R. (2026). Investigating the Magnetic Resonance Imaging Cross-sectional Area That Best Correlates with Intraoperative Hamstring Autograft Size. Annals of African Medicine. https://doi.org/10.4103/aam.aam_304_25
Vancouver
Gupta GK, Das AK, Prabhat V, Rani S, Chakraborty R. Investigating the Magnetic Resonance Imaging Cross-sectional Area That Best Correlates with Intraoperative Hamstring Autograft Size. Annals of African Medicine. 2026. doi:10.4103/aam.aam_304_25
BibTeX
@article{Gupta2026,
author = {Gupta, Govind Kumar and Das, Anil Kumar and Prabhat, Vinay and Rani, Sudha and Chakraborty, Ratnajeet},
title = {Investigating the Magnetic Resonance Imaging Cross-sectional Area That Best Correlates with Intraoperative Hamstring Autograft Size},
journal = {Annals of African Medicine},
year = {2026},
doi = {10.4103/aam.aam_304_25}
}
EUVIMED