Association of Bone Quality Measured by Noncontrast Computed Tomography Scan and Three-dimensional Computed Tomography-based Fracture Pattern in Intertrochanteric Femur Fracture in Adults
Annals of African Medicine · 2026
DOI: 10.4103/aam.aam_284_25 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of African Medicine, 2026. Verfasst von Govind Kumar Gupta und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Rajendra Institute of Medical Sciences, Ranchi, Jharkhand, India. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Imaging, Three-Dimensional, Bone Density, Hip Fractures. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
Understanding intertrochanteric (IT) femur fractures, their causes, classifications, and the role of bone quality is crucial for management. Poor bone quality associated with osteoporosis increases fracture risk and poorer outcomes. While dual-energy X-ray absorptiometry is the gold standard, Hounsfield units (HUs) derived from computed tomography (CT) scans are a valuable, noninvasive alternative for assessing bone quality. Aim and Objectives: To determine the association of bone quality, measured by noncontrast CT scan, with three-dimensional CT (3D-CT)-based fracture patterns in IT femur fractures in adults. Materials and Methods: Over a period of 18 months, 137 patients with IT femoral fractures were included. Fracture classification using Evans (1949), Boyd and Griffin (1956), and Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association (AO/OTA) (2018) was done. Bone quality was assessed by calculating the HU value from the largest spherical region of interest in the IT region of the unaffected side. 3D-CT-based classification system by Dr. R. B. Kalia and Dr. Shobha S. Arora was used.
Results
The mean age was 65.4 ± 10.2 years, with females comprising 59.9%. AO/OTA type 31A2.2 was the most common, indicating frequent unstable fractures. Patients with stable fractures had significantly higher mean HU values (130.2 ± 22.1) compared to those with unstable fractures (105.4 ± 24.3) ( P < 0.001). A significant correlation ( P < 0.001) between the AO/OTA (2018) classification and the CT-based classification is evident.
Conclusion
Lower HU values, indicating poorer bone quality, are strongly associated with unstable fracture patterns. The significant correlation between CT-based assessments and AO/OTA classification validates the utility of advanced imaging techniques in assessing bone strength and fracture risk.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedics, Rajendra Institute of Medical Sciences, Ranchi, Jharkhand, India.
- Department of Anatomy, Sheikh Bhikhari Medical College, Hazaribag, Jharkhand, India.
Zitieren
APA
Gupta, G. K., Kullu, S., Guria, A., Gourab, K., & Rani, S. (2026). Association of Bone Quality Measured by Noncontrast Computed Tomography Scan and Three-dimensional Computed Tomography-based Fracture Pattern in Intertrochanteric Femur Fracture in Adults. Annals of African Medicine. https://doi.org/10.4103/aam.aam_284_25
Vancouver
Gupta GK, Kullu S, Guria A, Gourab K, Rani S. Association of Bone Quality Measured by Noncontrast Computed Tomography Scan and Three-dimensional Computed Tomography-based Fracture Pattern in Intertrochanteric Femur Fracture in Adults. Annals of African Medicine. 2026. doi:10.4103/aam.aam_284_25
BibTeX
@article{Gupta2026,
author = {Gupta, Govind Kumar and Kullu, Saumya and Guria, Abhishek and Gourab, Kumar and Rani, Sudha},
title = {Association of Bone Quality Measured by Noncontrast Computed Tomography Scan and Three-dimensional Computed Tomography-based Fracture Pattern in Intertrochanteric Femur Fracture in Adults},
journal = {Annals of African Medicine},
year = {2026},
doi = {10.4103/aam.aam_284_25}
}
EUVIMED