Assessment of Pulmonary Function Tests in Patients with Hypothyroidism
Annals of African Medicine · 2026
DOI: 10.4103/aam.aam_190_25 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Annals of African Medicine, 2026. Verfasst von Nanak Laha und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, Rajendra Institute of Medical Sciences, Ranchi, Jharkhand, India. Hauptthemen laut MEDLINE: Hypothyroidism, Respiratory Function Tests. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background and Aims: Hypothyroid patients often complain of shortness of breath, fatigue, and exercise intolerance. Both inspiratory and expiratory muscles’ weakness is present, and the impairment of pulmonary function may be initiated at the subclinical stage of hypothyroidism. Hence, this study aimed to assess the pulmonary function tests (PFTs) in hypothyroid patients. Materials and Methods: This cross-sectional observational study was undertaken on patients attending the medicine outpatient department and indoor, in the Department of Medicine at Rajendra Institute of Medical Sciences, Ranchi, Jharkhand, from May 2023 to June 2024. Thyroid profile was estimated by enzyme-linked immunosorbent assay. PFTs (forced expiratory volume in 1 s [FEV1], forced vital capacity [FVC], and FEV1/FVC) were assessed by spirometry. Data were analyzed using SPSS software (version 22.0). Descriptive analysis was done for almost all variables along with t -test and Chi-square test wherever applicable for finding a significant difference using P value. Pearson’s correlation was used to determine the correlation between the variables.
Results
The study was conducted on 136 patients, of whom 26% were male and 74% were female. In this study, the mean thyroid-stimulating hormone, free triiodothyronine (T3), and free thyroxine (T4) levels were 19.6 ± 34.7 μIU/ml, 1.1 ± 0.794 ng/ml, and 2.9 ± 2.47 ng/ml, respectively. Spirometry results revealed a predominant restrictive pattern (75.74%). Peak expiratory flow rate (PEFR) had a mean value of 5.89 ± 1.91 L/min. This low level of PEFR suggests restrictive lung disease. Correlation analyses demonstrated a positive relationship between serum T4 levels with FVC ( P = 0.006) and serum T3 level with PEFR ( P = 0.041), indicating lower T3 and T4 levels associated with restrictive lung disease.
Conclusion
Pulmonary function tests can be affected in hypothyroidism with increased risk of restrictive lung disease.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Medicine, Rajendra Institute of Medical Sciences, Ranchi, Jharkhand, India.
- Department of TB and Chest, Rajendra Institute of Medical Sciences, Ranchi, Jharkhand, India.
- Department of Physiology, Rajendra Institute of Medical Sciences, Ranchi, Jharkhand, India.
- Department of Pediatrics, Rajendra Institute of Medical Sciences, Ranchi, Jharkhand, India.
Zitieren
APA
Laha, N., Prasad, M. K., Mishra, B., Kumar, D., Guria, R. T., Kumar, S., Deep, U., Prasad, M. L., Sinha, R., Sinha, M. B. K., & Chaudhuri, P. K. (2026). Assessment of Pulmonary Function Tests in Patients with Hypothyroidism. Annals of African Medicine. https://doi.org/10.4103/aam.aam_190_25
Vancouver
Laha N, Prasad MK, Mishra B, Kumar D, Guria RT, Kumar S, et al. Assessment of Pulmonary Function Tests in Patients with Hypothyroidism. Annals of African Medicine. 2026. doi:10.4103/aam.aam_190_25
BibTeX
@article{Laha2026,
author = {Laha, Nanak and Prasad, Manoj Kumar and Mishra, Brajesh and Kumar, Divakar and Guria, Rishi Tuhin and Kumar, Satish and Deep, Ujjwal and Prasad, Manohar Lal and Sinha, Rashmi and Sinha, Mani Bhushan Kumar and Chaudhuri, Partha Kumar},
title = {Assessment of Pulmonary Function Tests in Patients with Hypothyroidism},
journal = {Annals of African Medicine},
year = {2026},
doi = {10.4103/aam.aam_190_25}
}
EUVIMED