Effects of metronome use on cardiopulmonary resuscitation quality
Turkish Journal of Emergency Medicine · 2021-04 · 21 (2) · 51-55
DOI: 10.4103/2452-2473.309137 ↗Kurz gefasst
Fachartikel in der Zeitschrift Turkish Journal of Emergency Medicine, 2021-04. Verfasst von Dikmen Çalışkan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Emergency Service, Antalya Kepez State Hospital, Antalya, Turkey. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Themen: Reanimation
Abstract (Originalsprache)
OBJECTIVE: Whether the use of metronome affects the quality of cardiopulmonary resuscitation (CPR) remains unclear. In this study, we investigated the effect of metronome use on CPR quality. METHODS: This was a prospective, simulation-based CPR manikin study. There were two phases: without and with metronome use. Chest compression was performed for 2 min, and three CPR quality criteria including chest compression depth, recoil, and rate were recorded with TrueCPR Feedback Device in both phases. RESULTS: In all, 102 resident physicians were included. The achievement of optimal chest compression depth and complete recoil was better with metronome use than without (83% and 77% vs. 78% and 39%, P ≤ 0.001, respectively). Optimal chest compression rate was also reached with metronome use because the range of the compression rate was closer to the normal limits than those without metronome use (110 [interquartile range (IQR) 109–113] vs. 120 [IQR 109–129], P ≤ 0.001). Of all the participants, 70.6% stated that metronome use had a positive effect on their performance during the CPR application and 66.7% stated that they wished to use the metronome in their daily practice. CONCLUSION: Using a metronome during simulation-based CPR improved the compression depth and recoil by fixing chest compression rate. We suggested that metronome should be used in CPR trainings of health-care professionals.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Emergency Service, Antalya Kepez State Hospital, Antalya, Turkey.
- Department of Emergency, Gazi University School of Medicine, Ankara, Turkey.
ORCID-Profile: Dikmen Çalışkan, Fikret Bildik, Mehmet Ali Aslaner, İsa Kılıçaslan, Ayfer Keleş, Ahmet Demircan
Zitieren
APA
Çalışkan, D., Bildik, F., Aslaner, M. A., Kılıçaslan, İ., Keleş, A., & Demircan, A. (2021). Effects of metronome use on cardiopulmonary resuscitation quality. Turkish Journal of Emergency Medicine, 21(2), 51-55. https://doi.org/10.4103/2452-2473.309137
Vancouver
Çalışkan D, Bildik F, Aslaner MA, Kılıçaslan İ, Keleş A, Demircan A. Effects of metronome use on cardiopulmonary resuscitation quality. Turkish Journal of Emergency Medicine. 2021;21(2):51-55. doi:10.4103/2452-2473.309137
BibTeX
@article{alkan2021,
author = {Çalışkan, Dikmen and Bildik, Fikret and Aslaner, Mehmet Ali and Kılıçaslan, İsa and Keleş, Ayfer and Demircan, Ahmet},
title = {Effects of metronome use on cardiopulmonary resuscitation quality},
journal = {Turkish Journal of Emergency Medicine},
year = {2021},
volume = {21},
number = {2},
pages = {51--55},
doi = {10.4103/2452-2473.309137}
}