Comparison of shaping ability of three different rotary instruments in simulated root canals using computer image analysis: An in vitro study

SUma Maheswari, JonathanEmil Sam, AArvind Kumar, Jacob Raja, RGnana Seelan, T. S. P.Ram Balaji

Journal of Indian Academy of Dental Specialist Researchers · 2015

DOI: 10.4103/2229-3019.166098 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Indian Academy of Dental Specialist Researchers, 2015. Verfasst von SUma Maheswari und 5 weiteren Autor:innen. Die Arbeit nennt 15 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

This in vitro study was done to compare the shaping ability of ProTaper, K3, and Hero Shapers in clear resin blocks with simulated root canals using computer image software analysis. Materials and Methods: 45 clear resin blocks with simulated root canals were divided into three groups of 15 each. Preinstrumentation digitalized images of the blocks were made and stored. Each group was instrumented with ProTaper, K3, and Hero Shapers, respectively. Postinstrumentation images of the blocks were made after injecting a contrast medium to improve the outlines of the root canals. Pre- and post-instrumentation images were magnified, superimposed, and assessed using computer image analysis program (pattern matching analysis). Material removal was measured at nine points in the inner wall and outer wall ending 1 cm from the apical terminus. Statistical Analysis: Student's t-test and one-way analysis of variance were used to compare the overall change in the width in the mesial view by using ProTaper, K3, and Hero Shapers.

Results

ProTaper showed more change in width, followed by K3 and Hero Shapers.

Conclusion

ProTaper and K3 showed significant removal of material in the outer wall of the coronal and apical 3 rd , followed by inner wall of the middle 3 rd . Hero Shapers showed significant removal of material in the outer wall of coronal 3 rd , with less significant changes in the middle 3 rd and even material removal in the apical 3 rd .

Zitieren

APA

Maheswari, S., Sam, J., Kumar, A., Raja, J., Seelan, R., & Balaji, T. S. P. (2015). Comparison of shaping ability of three different rotary instruments in simulated root canals using computer image analysis: An in vitro study. Journal of Indian Academy of Dental Specialist Researchers. https://doi.org/10.4103/2229-3019.166098

Vancouver

Maheswari S, Sam J, Kumar A, Raja J, Seelan R, Balaji TSP. Comparison of shaping ability of three different rotary instruments in simulated root canals using computer image analysis: An in vitro study. Journal of Indian Academy of Dental Specialist Researchers. 2015. doi:10.4103/2229-3019.166098

BibTeX
@article{Maheswari2015,
  author = {Maheswari, SUma and Sam, JonathanEmil and Kumar, AArvind and Raja, Jacob and Seelan, RGnana and Balaji, T. S. P.Ram},
  title = {Comparison of shaping ability of three different rotary instruments in simulated root canals using computer image analysis: An in vitro study},
  journal = {Journal of Indian Academy of Dental Specialist Researchers},
  year = {2015},
  doi = {10.4103/2229-3019.166098}
}
Kostenlos starten →