Effect of anterior chamber depth on the choice of intraocular lens calculation formula in patients with normal axial length
Middle East African Journal of Ophthalmology · 2014 · 21 (4) · 307
DOI: 10.4103/0974-9233.142266 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Middle East African Journal of Ophthalmology, 2014. Verfasst von Mohammad Miraftab und 5 weiteren Autor:innen. Beteiligte Einrichtung: Noor Ophthalmology Research Center, Noor Eye Hospital, Tehran, Iran. Hauptthemen laut MEDLINE: Lens Implantation, Intraocular, Lenses, Intraocular, Optics and Photonics. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
PURPOSE: To compare the accuracy of Sanders-Retzlaff-Kraff II (SRK II) and 3(rd) and 4(th) generation intraocular lens (IOL) formulas and to compare the effect of different anterior chamber depths among the IOL formulas in cataract patients with normal axial length (AL; 22.0-24.5 millimeters, mm). MATERIALS AND METHODS: A retrospective chart review was performed of patients with normal AL who underwent cataract surgery. The SRK II and 3(rd) generation IOL formulas (Hoffer Q, SRK T, Holladay 1) were compared to the 4(th) generation Haigis formula. For analysis, preoperative anterior chamber depth (ACD) was divided into three subgroups: ≤3, 3-3.5, and ≥ 3.5 mm. The mean error (ME) and mean absolute error (MAE) of each formula was compared for each subgroup against the total. The difference between the ME and MAE of the formulas were compared for each ACD subgroup. P 0.05, all comparisons). CONCLUSION: The SRK II formula can predict refraction in patients with normal AL and ACD less than 3 mm with less error and is preferred over other formulas. The Haigis formula is the preferred choice in patients with a normal AL and ACD longer than 3.5 mm. The prediction accuracy of Hoffer Q, SRK T, and Holladay 1 is comparable in normal AL.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Noor Ophthalmology Research Center, Noor Eye Hospital, Tehran, Iran.
- Department of Epidemiology and Biostatistics, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran.
- Noor Ophthalmology Research Center, Noor Eye Hospital, Tehran, Iran ; Dezful University of Medical Sciences, Dezful, Iran.
- Noor Ophthalmology Research Center, Noor Eye Hospital, Tehran, Iran ; Department of Epidemiology and Biostatistics, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran ; International Campus (TU…
Zitieren
APA
Miraftab, M., Hashemi, H., Fotouhi, A., Khabazkhoob, M., Rezvan, F., & Asgari, S. (2014). Effect of anterior chamber depth on the choice of intraocular lens calculation formula in patients with normal axial length. Middle East African Journal of Ophthalmology, 21(4), 307. https://doi.org/10.4103/0974-9233.142266
Vancouver
Miraftab M, Hashemi H, Fotouhi A, Khabazkhoob M, Rezvan F, Asgari S. Effect of anterior chamber depth on the choice of intraocular lens calculation formula in patients with normal axial length. Middle East African Journal of Ophthalmology. 2014;21(4):307. doi:10.4103/0974-9233.142266
BibTeX
@article{Miraftab2014,
author = {Miraftab, Mohammad and Hashemi, Hassan and Fotouhi, Akbar and Khabazkhoob, Mehdi and Rezvan, Farhad and Asgari, Soheila},
title = {Effect of anterior chamber depth on the choice of intraocular lens calculation formula in patients with normal axial length},
journal = {Middle East African Journal of Ophthalmology},
year = {2014},
volume = {21},
number = {4},
pages = {307},
doi = {10.4103/0974-9233.142266}
}
EUVIMED