EUVIMEDEUVIMED entdecken
Crossref

Automated detection of malaria with haematology analyzer sysmex xe-2100

Sarita Mohapatra, JyotishC Samantaray, S Arulselvi, Jitender Panda, Khushboo Munot, Renu Saxena

Indian Journal of Medical Sciences · 2011 · 65 (1) · 26

DOI: 10.4103/0019-5359.103163 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indian Journal of Medical Sciences, 2011. Verfasst von Sarita Mohapatra und 5 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Diagnosis of malaria is usually made by microscopy [Giemsa, Acridine Orange (AO), and Quantitative Buffy Coat (QBC) assay], which requires expertise. Currently, automated haematology analyzers are being used for complete blood count (CBC), in all acute febrile and non-febrile illnesses which simultaneously detects malaria. The normal scattergram by the analyzer (Sysmex 2100) comprises of five parameters i.e. lymphocytes (pink), monocytes (green), neutrophils (blue), eosinophils (red) with a space between the neutrophil and eosinophil populations. AIMS: We carried out a prospective study to compare the efficacy of Sysmex XE-2100 (Sysmex Corporation, Kobe) for detection of malaria in comparison to other conventional techniques. MATERIALS AND METHODS: 430 cases were analyzed for malaria by microscopy (QBC, AO, Giemsa), ICT (Immunochromatography) and flowcytometric analyzer (Sysmex XE-2100). The abnormal scattergrams were observed as double neutrophil, double eosinophil, grey zone, extended neutrophil zone with a decrease space between eosinophil and neutrophil, and a combination of above patterns. RESULTS: Out of 70 positive cases [49/70 (70%) P. vivax, 18/70 (25.7%) P. falciparum, and 3/70 (4.2%) both P. vivax and P. falciparum], 52 showed abnormal scattergrams by the analyzer. The sensitivity and specificity of hematology analyzer found to be 74.2% and 88%, respectively. CONCLUSION: Flowcytometric analyzer is a rapid, high throughput device which needs less expertization for the diagnosis of malaria. Hence, it can be used in the diagnostic laboratories as an early modality for diagnosis of malaria in suspected as well as clinically in apparent cases.

Zitieren

APA

Mohapatra, S., Samantaray, J., Arulselvi, S., Panda, J., Munot, K., & Saxena, R. (2011). Automated detection of malaria with haematology analyzer sysmex xe-2100. Indian Journal of Medical Sciences, 65(1), 26. https://doi.org/10.4103/0019-5359.103163

Vancouver

Mohapatra S, Samantaray J, Arulselvi S, Panda J, Munot K, Saxena R. Automated detection of malaria with haematology analyzer sysmex xe-2100. Indian Journal of Medical Sciences. 2011;65(1):26. doi:10.4103/0019-5359.103163

BibTeX
@article{Mohapatra2011,
  author = {Mohapatra, Sarita and Samantaray, JyotishC and Arulselvi, S and Panda, Jitender and Munot, Khushboo and Saxena, Renu},
  title = {Automated detection of malaria with haematology analyzer sysmex xe-2100},
  journal = {Indian Journal of Medical Sciences},
  year = {2011},
  volume = {65},
  number = {1},
  pages = {26},
  doi = {10.4103/0019-5359.103163}
}
Kostenlos starten →