EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Appropriate glycated haemoglobin testing frequency to monitor patients with type 2 diabetes

Wade Thompson, Tom Perry, Guillaume Grenet, Ken Bassett, Anshula Ambasta

African Journal of Primary Health Care & Family Medicine · 29.09.2026 · 18 (1)

DOI: 10.4102/phcfm.v18i1.5614 ↗

Kurz gefasst

Fachartikel in der Zeitschrift African Journal of Primary Health Care & Family Medicine, online erschienen am 29.09.2026. Verfasst von Wade Thompson und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anaesthesiology, Pharmacology, and Therapeutics, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia. wade…. Hauptthemen laut MEDLINE: Diabetes Mellitus, Type 2, Glycated Hemoglobin, Glycemic Control. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Glycated haemoglobin (HbA1c) is used to monitor glycaemic control among patients with type 2 diabetes (T2DM). Glycated haemoglobin represents a 3-month glycaemic average, with the most recent 6 weeks of glycaemia having the greatest influence. Analytical and biological variation introduce imprecision into any single HbA1c, where a result of 7.5% may represent a ‘true’ value between 6.8% and 8.2%. This Therapeutics Letter evaluates the most appropriate interval for monitoring HbA1c in T2DM. Evidence was synthesised from a pragmatic randomised controlled trial (RCT) and three large observational studies. In the RCT, 94% of patients monitored every 6 months maintained good glycaemic control compared to 92% of those monitored every 3 months. Observational data indicated that 3-month testing resulted in a clinically unimportant difference in HbA1c compared with 6-month testing. Furthermore, patients tested 2–3 times annually were as likely to achieve personalised goals as those tested four times per year. Testing more than four times annually was associated with a lower probability of achieving targets. For patients with stable T2DM meeting glycaemic goals, monitoring HbA1c every 6 months is as effective as every 3 months and could be contemplated for many patients following a discussion of patient goals and preferences. Frequent testing may be reserved for periods of medication adjustment, changes in health status or when targets are unmet. Reducing testing frequency in stable patients minimises low-value data, reduces the carbon footprint of lab testing and improves patient convenience without compromising clinical outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diabetes Mellitus, Type 2Glycated HemoglobinGlycemic ControlHumansBlood GlucoseHypoglycemic AgentsTime Factors

Stichwörter der Autor:innen

HBA1c testing frequencyblood glucosediabetes mellitusglycated haemoglobinolder peoplephysiologic monitoring

Substanzen

Glycated HemoglobinBlood GlucoseHypoglycemic Agents

Autor:innen und Institutionen

  • Department of Anaesthesiology, Pharmacology, and Therapeutics, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia. wade.thompson@ubc.ca.

Zitieren

APA

Thompson, W., Perry, T., Grenet, G., Bassett, K., & Ambasta, A. (2026). Appropriate glycated haemoglobin testing frequency to monitor patients with type 2 diabetes. African Journal of Primary Health Care & Family Medicine, 18(1). https://doi.org/10.4102/phcfm.v18i1.5614

Vancouver

Thompson W, Perry T, Grenet G, Bassett K, Ambasta A. Appropriate glycated haemoglobin testing frequency to monitor patients with type 2 diabetes. African Journal of Primary Health Care & Family Medicine. 2026;18(1). doi:10.4102/phcfm.v18i1.5614

BibTeX
@article{Thompson2026,
  author = {Thompson, Wade and Perry, Tom and Grenet, Guillaume and Bassett, Ken and Ambasta, Anshula},
  title = {Appropriate glycated haemoglobin testing frequency to monitor patients with type 2 diabetes},
  journal = {African Journal of Primary Health Care & Family Medicine},
  year = {2026},
  volume = {18},
  number = {1},
  doi = {10.4102/phcfm.v18i1.5614}
}
Kostenlos starten →