Audit of handling haemolysed, lipaemic and icteric samples in KwaZulu-Natal chemical pathology laboratories
The Journal of Medical Laboratory Science & Technology of South Africa · 25.06.2026 · 8 (1)
DOI: 10.4102/jmlstsa.v8i1.129 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Medical Laboratory Science & Technology of South Africa, online erschienen am 25.06.2026. Verfasst von Lamla L.-R. Siganagana und 2 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Pre-analytical errors in laboratory testing, such as haemolysis (release of haemoglobin and intracellular components), icterus (elevated bilirubin), and lipaemia (high lipid levels) collectively known as high concentrations of lipids (HIL) are common. Their detection, reporting, and mitigation require proper protocols.
Aim
This study assessed practices in handling chemistry samples affected by HIL within public laboratories in KwaZulu-Natal (KZN), focusing on detection methods and rejection monitoring.
Setting
This study was conducted at the National Health Laboratory Service (NHLS) chemistry laboratory at Inkosi Albert Luthuli Central Hospital, Durban, South Africa, between 01 August 2021 and 31 October 2021.
Methods
Standardised questionnaires were distributed to NHLS laboratories in KZN. Data from the NHLS Central Data Warehouse (August 2021 – October 2021) were extracted for commonly ordered chemistry panels (urea, electrolytes, liver function tests) to review HIL reporting. Analysis was performed using Microsoft Excel.
Results
Detection and management of HIL samples varied. Most laboratories did not report HIL interference, even with abnormal results, potentially compromising patient care. Failure to disclose interference reduces accuracy and reliability, affecting diagnosis and treatment. Some laboratories rejected haemolysed samples regardless of severity. For icterus and lipaemia, many laboratories did not specify corrective measures such as ultracentrifugation, microcentrifugation, or dilution.
Conclusion
Practices for detecting and managing HIL interference are inconsistent across KZN laboratories. A lack of standardised reporting and unclear handling protocols for icterus and lipaemia highlight the need for improved guidelines to ensure reliable patient results. Contribution: This study provides insight into how NHLS laboratories in KZN were handling specimens affected by HIL.
Zitieren
APA
Siganagana, L. L., Gounden, V., & Ngxamngxa, U. (2026). Audit of handling haemolysed, lipaemic and icteric samples in KwaZulu-Natal chemical pathology laboratories. The Journal of Medical Laboratory Science & Technology of South Africa, 8(1). https://doi.org/10.4102/jmlstsa.v8i1.129
Vancouver
Siganagana LL, Gounden V, Ngxamngxa U. Audit of handling haemolysed, lipaemic and icteric samples in KwaZulu-Natal chemical pathology laboratories. The Journal of Medical Laboratory Science & Technology of South Africa. 2026;8(1). doi:10.4102/jmlstsa.v8i1.129
BibTeX
@article{Siganagana2026,
author = {Siganagana, Lamla L.-R. and Gounden, Verena and Ngxamngxa, Unathi},
title = {Audit of handling haemolysed, lipaemic and icteric samples in KwaZulu-Natal chemical pathology laboratories},
journal = {The Journal of Medical Laboratory Science & Technology of South Africa},
year = {2026},
volume = {8},
number = {1},
doi = {10.4102/jmlstsa.v8i1.129}
}