EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Baseline pupil size predicts dilation rate with 1% tropicamide in a young African population

Michael Ntodie, Enoch Eduaful, Carl H. Abraham, Osbert D. Antwi, Khathutshelo P. Mashige

African Vision and Eye Health · 2025

DOI: 10.4102/aveh.v84i1.1002 ↗

Kurz gefasst

Fachartikel in der Zeitschrift African Vision and Eye Health, 2025. Verfasst von Michael Ntodie und 4 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The use of ophthalmic topical agents is critical to the success of several ophthalmic diagnostic procedures, particularly posterior segment examination.

Aim

This study investigated the relationship between age, gender, and anterior segment biometry and pupillary dilation dynamics using 1% Tropicamide ophthalmic solution in a young African population.

Setting

The study took place at the School of Optometry eye clinic, University of Cape Coast, Ghana.

Methods

A pre-test–post-test study design was utilised, involving 51 participants of Black African descent with dark irides, classified according to the Franssen reference set. Baseline anterior segment biometric parameters, including central corneal thickness (CCT), anterior chamber depth (ACD), and pupillary diameter (PD) of one randomly chosen eye, were measured using the Cirrus High Definition-Optical Coherence Tomography (HD-OCT) system. Following baseline assessment, a drop of 1% tropicamide was instilled in a randomly selected eye of each participant. Subsequent PD measurements were obtained at five-minute intervals over a 30-minute period using the Cirrus HD-OCT. All data collection took place in a dark room set up.

Results

The mean baseline pupillary diameter (PD) was 4.31 ± 0.67 mm, with a total change of 2.00 ± 0.73 mm over 30 minutes. No significant correlations were found between the rate of pupillary dilation and age, anterior chamber depth (ACD), or central corneal thickness (CCT) (P > 0.05). However, the rate of dilation showed a significant negative correlation with baseline PD (r = –0.54, P < 0.001).

Conclusion

Smaller baseline pupils dilated faster, indicating baseline pupil size may predict individual dilation dynamics for diagnostic or therapeutic applications. Contribution: The results of this study provide data that could optimise the use of tropicamide 1% for pupillary dilation in young African populations.

Zitieren

APA

Ntodie, M., Eduaful, E., Abraham, C. H., Antwi, O. D., & Mashige, K. P. (2025). Baseline pupil size predicts dilation rate with 1% tropicamide in a young African population. African Vision and Eye Health. https://doi.org/10.4102/aveh.v84i1.1002

Vancouver

Ntodie M, Eduaful E, Abraham CH, Antwi OD, Mashige KP. Baseline pupil size predicts dilation rate with 1% tropicamide in a young African population. African Vision and Eye Health. 2025. doi:10.4102/aveh.v84i1.1002

BibTeX
@article{Ntodie2025,
  author = {Ntodie, Michael and Eduaful, Enoch and Abraham, Carl H. and Antwi, Osbert D. and Mashige, Khathutshelo P.},
  title = {Baseline pupil size predicts dilation rate with 1% tropicamide in a young African population},
  journal = {African Vision and Eye Health},
  year = {2025},
  doi = {10.4102/aveh.v84i1.1002}
}
Kostenlos starten →