EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieVergleichsstudieOpen Access · CC BY-NC 4.0

Ramped versus sniffing position for Ambu® AuraGainTM insertion in patients with obesity: a randomized controlled study

Hye-Won Jeong, Hong-Beom Bae, Leyeoin Lee, Woojeong Lee, Joungmin Kim

Korean Journal of Anesthesiology · 01.10.2024 · 77 (5) · 518-525

DOI: 10.4097/kja.24255 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Korean Journal of Anesthesiology, erschienen am 01.10.2024. Verfasst von Hye-Won Jeong und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Pain Medicine, Chonnam National University Hospital, Gwangju, Korea. Hauptthemen laut MEDLINE: Obesity, Intubation, Intratracheal. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The ramped position facilitates mask ventilation and endotracheal intubation in patients with obesity. This study aimed to determine whether the ramped position improves supraglottic airway (SGA) insertion in patients with obesity.

Methods

In this prospective, randomized, single-center trial, 48 obese patients undergoing elective surgery were randomized into either ramped or sniffing position groups. The Ambu® AuraGainTM (Ambu A/S), a second-generation SGA, was used. The primary outcome was the time required for the AuraGain insertion. Secondary outcomes included ease and number of insertion attempts, oropharyngeal leak pressure (OLP), and complications. The number needed to treat (NNT) was calculated to ensure ease of insertion.

Results

The time required for the AuraGain insertion was significantly shorter in the ramped group than in the sniffing group (13.0 [11.0, 16.0] vs. 24.0 [21.0, 28.0], P < 0.001). The insertion was easier in the ramped group than in the sniffing group (23/24 vs. 13/24, NNT = 2.4 [95% CI, 1.6, 5.0], P = 0.003). The first-attempt success rate was higher in the ramped group than in the sniffing group, although the difference was not statistically significant (22/24 vs. 18/24, P = 0.319). The OLP and postoperative complication rates were not significantly different between the groups.

Conclusions

The ramped position reduced the time required for the AuraGain insertion in obese patients while providing comparable airway sealing without increasing adverse events. Therefore, a ramped position may be a more suitable option for SGA insertion in this population.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ObesityIntubation, IntratrachealHumansMaleFemaleProspective StudiesMiddle AgedAdultLaryngeal MasksPatient PositioningAged

Stichwörter der Autor:innen

Airway managementLaryngeal masksNumbers needed to treatObesityPatient positioningPosture.

Autor:innen und Institutionen

  • Department of Anesthesiology and Pain Medicine, Chonnam National University Hospital, Gwangju, Korea.
  • Department of Anesthesiology and Pain Medicine, Chonnam National University Hwasun Hospital, Hwasun, Korea.
  • Department of Anesthesiology and Pain Medicine, Chonnam National University Medical School, Gwangju, Korea.

Zitieren

APA

Jeong, H. W., Bae, H. B., Lee, L., Lee, W., & Kim, J. (2024). Ramped versus sniffing position for Ambu® AuraGainTM insertion in patients with obesity: a randomized controlled study. Korean Journal of Anesthesiology, 77(5), 518-525. https://doi.org/10.4097/kja.24255

Vancouver

Jeong HW, Bae HB, Lee L, Lee W, Kim J. Ramped versus sniffing position for Ambu® AuraGainTM insertion in patients with obesity: a randomized controlled study. Korean Journal of Anesthesiology. 2024;77(5):518-525. doi:10.4097/kja.24255

BibTeX
@article{Jeong2024,
  author = {Jeong, Hye-Won and Bae, Hong-Beom and Lee, Leyeoin and Lee, Woojeong and Kim, Joungmin},
  title = {Ramped versus sniffing position for Ambu® AuraGainTM insertion in patients with obesity: a randomized controlled study},
  journal = {Korean Journal of Anesthesiology},
  year = {2024},
  volume = {77},
  number = {5},
  pages = {518--525},
  doi = {10.4097/kja.24255}
}
Kostenlos starten →