Randomisierte kontrollierte Studie in der Zeitschrift Korean Journal of Anesthesiology, 2024. Verfasst von A R Karthik und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Cancer Institute (WIA), Adyar, Chennai, India. Hauptthemen laut MEDLINE: Positive-Pressure Respiration, Feasibility Studies, Electric Impedance, Postoperative Complications. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Existing literature lacks high-quality evidence regarding the ideal intraoperative positive end-expiratory pressure (PEEP) to minimize postoperative pulmonary complications (PPCs). We hypothesized that applying individualized PEEP derived from electrical impedance tomography would reduce the severity of postoperative lung aeration loss, deterioration in oxygenation, and PPC incidence.

Methods

A pilot feasibility study was conducted on 36 patients who underwent open abdominal oncologic surgery. The patients were randomized to receive individualized PEEP or conventional PEEP at 4 cmH2O. The primary outcome was the impact of individualized PEEP on changes in the modified lung ultrasound score (MLUS) derived from preoperative and postoperative lung ultrasonography. A higher MLUS indicated greater lung aeration loss. The secondary outcomes were the PaO2/FiO2 ratio and PPC incidence.

Results

A significant increase in the postoperative MLUS (12.0 ± 3.6 vs 7.9 ± 2.1, P < 0.001) and a significant difference between the postoperative and preoperative MLUS values (7.0 ± 3.3 vs 3.0 ± 1.6, P < 0.001) were found in the conventional PEEP group, indicating increased lung aeration loss. In the conventional PEEP group, the intraoperative PaO2/FiO2 ratios were significantly lower but not the postoperative ratios. The PPC incidence was not significantly different between the groups. Post-hoc analysis showed the increase in lung aeration loss and deterioration of intraoperative oxygenation correlated with the deviation from the individualized PEEP.

Conclusions

Individualized PEEP appears to protect against lung aeration loss and intraoperative oxygenation deterioration. The advantage was greater in patients whose individualized PEEP deviated more from the conventional PEEP.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Positive-Pressure RespirationFeasibility StudiesElectric ImpedancePostoperative ComplicationsTomographyHumansPilot ProjectsMaleFemaleMiddle AgedAgedAbdominal NeoplasmsLungUltrasonographyAdult

Stichwörter der Autor:innen

Electric impedanceFeasibility studiesGeneral anesthesiaLaparotomyLung compliancePositive-pressure respirationPulmonary atelectasis

Autor:innen und Institutionen

  • Department of Anesthesiology, Cancer Institute (WIA), Adyar, Chennai, India.
  • Department of Onco-Anesthesia and Palliative Medicine, Dr. B.R.A. Institute Rotary Cancer Hospital, AIIMS, Ansari Nagar, New Delhi, India.
  • Department of Surgical Oncology, Dr. B.R.A. Institute Rotary Cancer Hospital, AIIMS, Ansari Nagar, New Delhi, India.
  • Department of Pulmonary, Critical Care and Sleep Medicine, AIIMS, Ansari Nagar, New Delhi, India.
  • Department of Pulmonary Medicine, Amrita Hospital, Faridabad, India.
  • Department of Anesthesiology, University of Minnesota Medical School, Minneapolis, MN, USA.

Zitieren

APA

Karthik, A. R., Gupta, N., Garg, R., Bharati, S. J., Ray, M. D., Hadda, V., Pahuja, S., Mishra, S., Bhatnagar, S., & Kumar, V. (2024). Comparison of lung aeration loss in open abdominal oncologic surgeries after ventilation with electrical impedance tomography-guided PEEP versus conventional PEEP: a pilot feasibility study. Korean Journal of Anesthesiology. https://doi.org/10.4097/kja.23858

Vancouver

Karthik AR, Gupta N, Garg R, Bharati SJ, Ray MD, Hadda V, et al. Comparison of lung aeration loss in open abdominal oncologic surgeries after ventilation with electrical impedance tomography-guided PEEP versus conventional PEEP: a pilot feasibility study. Korean Journal of Anesthesiology. 2024. doi:10.4097/kja.23858

BibTeX
@article{Karthik2024,
  author = {Karthik, A R and Gupta, Nishkarsh and Garg, Rakesh and Bharati, Sachidanand Jee and Ray, M D and Hadda, Vijay and Pahuja, Sourabh and Mishra, Seema and Bhatnagar, Sushma and Kumar, Vinod},
  title = {Comparison of lung aeration loss in open abdominal oncologic surgeries after ventilation with electrical impedance tomography-guided PEEP versus conventional PEEP: a pilot feasibility study},
  journal = {Korean Journal of Anesthesiology},
  year = {2024},
  doi = {10.4097/kja.23858}
}
Kostenlos starten →