EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY-NC 4.0

Use of the Disposcope endoscope for awake orotracheal intubation in an elderly patient with a large vocal cord polyp -a case report-

Duo Yang, Sen Li, Jinxin Lan, Shujun Ye, Longsheng Zhang

Korean Journal of Anesthesiology · 2024

DOI: 10.4097/kja.23810 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Korean Journal of Anesthesiology, 2024. Verfasst von Duo Yang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Jieyang People's Hospital, Jieyang, Guangdong Province, China. Hauptthemen laut MEDLINE: Intubation, Intratracheal, Polyps, Vocal Cords. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Vocal cord polyps are commonly encountered in the otorhinolaryngology department. The risk of anesthesia is high in patients with large vocal cord polyps. Awake intubation with appropriate airway tools provides a favorable safety profile.Case: We present the case of a 60-year-old male patient who had been suffering from a large vocal cord polyp for 16 years. Electronic laryngoscopy revealed that the vocal cord polyp was approximately 1.5 cm in diameter. The polyp had a pedicle and demonstrated synchronous motion with respiratory excursion. It covered almost the entire glottic area during inspiration and moved away from the glottis during expiration. A Disposcope endoscope was used for awake tracheal intubation, and the surgery was completed successfully.

Conclusions

The Disposcope endoscope can be a useful option for awake orotracheal intubation in cases of anticipated difficult intubation and difficult facemask ventilation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Intubation, IntratrachealPolypsVocal CordsHumansMaleMiddle AgedLaryngoscopyWakefulnessLaryngeal DiseasesLaryngoscopes

Stichwörter der Autor:innen

Airway managementAirway obstructionAnesthesiaPatient safetyTracheal stenosisVocal cords.

Autor:innen und Institutionen

  • Department of Anesthesiology, Jieyang People's Hospital, Jieyang, Guangdong Province, China.
  • The First Clinical Medical College, Guangdong Medical University, Zhanjiang, Guangdong Province, China.

Zitieren

APA

Yang, D., Li, S., Lan, J., Ye, S., & Zhang, L. (2024). Use of the Disposcope endoscope for awake orotracheal intubation in an elderly patient with a large vocal cord polyp -a case report-. Korean Journal of Anesthesiology. https://doi.org/10.4097/kja.23810

Vancouver

Yang D, Li S, Lan J, Ye S, Zhang L. Use of the Disposcope endoscope for awake orotracheal intubation in an elderly patient with a large vocal cord polyp -a case report-. Korean Journal of Anesthesiology. 2024. doi:10.4097/kja.23810

BibTeX
@article{Yang2024,
  author = {Yang, Duo and Li, Sen and Lan, Jinxin and Ye, Shujun and Zhang, Longsheng},
  title = {Use of the Disposcope endoscope for awake orotracheal intubation in an elderly patient with a large vocal cord polyp -a case report-},
  journal = {Korean Journal of Anesthesiology},
  year = {2024},
  doi = {10.4097/kja.23810}
}