Programmed intermittent epidural bolus as an ideal method for labor analgesia: a randomized controlled trial
Korean Journal of Anesthesiology · 01.02.2024 · 77 (1) · 106-114
DOI: 10.4097/kja.23173 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Korean Journal of Anesthesiology, erschienen am 01.02.2024. Verfasst von Doyeon Kim und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Pain Medicine, CHA Bundang Medical Center, CHA University School of Medicine, Seongnam, Korea. Hauptthemen laut MEDLINE: Breakthrough Pain, Analgesia, Epidural. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Background
Although programmed intermittent epidural bolus (PIEB) is effective for labor analgesia, an appropriate flow rate has not been established. Therefore, we investigated the analgesic effect based on different epidural injection flow rates.
Methods
Nulliparous women scheduled for spontaneous labor were enrolled in this randomized trial. After injection of intrathecal 0.2% ropivacaine 3 mg with fentanyl 20 μg, participants were randomized to three study groups. Epidural analgesics, 10 ml during one hour, were administered with patient controlled epidural analgesia as follows (0.2% ropivacaine 60 ml, fentanyl 180 μg, and 0.9% saline 40 ml): continuous (n = 28, 10 ml/h for continuous infusion), PIEB (n = 29, 240 ml/h for bolus infusion of 10 ml), or manual (n = 28, 1200 ml/h for bolus injection of 10 ml). The primary outcome was hourly consumption of the epidural solution. The time interval between labor analgesia and the first breakthrough pain was investigated.
Results
The median (Q1, Q3) hourly consumption of epidural anesthetics was significantly different among the groups (continuous: 14.3 [8.7, 16.9] ml, PIEB: 9.4 [6.2, 9.8] ml, manual: 8.6 [7.6, 9.9] ml; P < 0.001). The time to breakthrough pain for the PIEB group was longer than that for the other groups (continuous: 78.5 [35.8, 185.0] min, PIEB: 200.0 [88.5, 441.5] min, manual: 60.5 [37.3, 162.0] min, P = 0.027).
Conclusions
PIEB, with a low-flow rate, provided more adequate labor analgesia than a continuous epidural infusion or manual injection with a high-flow rate.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Anesthesiology and Pain Medicine, CHA Bundang Medical Center, CHA University School of Medicine, Seongnam, Korea.
- Department of Anesthesiology and Pain Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
- Department of Anesthesiology and Pain Medicine, Inha University Hospital, Inha University School of Medicine, Incheon, Korea.
- Department of Anesthesiology and Pain Medicine, Dongtan Sacred Heart Hospital, Hallym University School of Medicine, Hwaseong, Korea.
Zitieren
APA
Kim, D., Kim, J., Choo, H., & Choi, D. H. (2024). Programmed intermittent epidural bolus as an ideal method for labor analgesia: a randomized controlled trial. Korean Journal of Anesthesiology, 77(1), 106-114. https://doi.org/10.4097/kja.23173
Vancouver
Kim D, Kim J, Choo H, Choi DH. Programmed intermittent epidural bolus as an ideal method for labor analgesia: a randomized controlled trial. Korean Journal of Anesthesiology. 2024;77(1):106-114. doi:10.4097/kja.23173
BibTeX
@article{Kim2024,
author = {Kim, Doyeon and Kim, Jeayoun and Choo, Hyeonju and Choi, Duck Hwan},
title = {Programmed intermittent epidural bolus as an ideal method for labor analgesia: a randomized controlled trial},
journal = {Korean Journal of Anesthesiology},
year = {2024},
volume = {77},
number = {1},
pages = {106--114},
doi = {10.4097/kja.23173}
}
EUVIMED