EUVIMEDEUVIMED entdecken
Crossref

Determinants of Discordance between Estimated and Measured HbA1c: The Role of Active Time in 14-Day Continuous Glucose Monitoring Data

Jee Hee Yoo, Seohyun Kim, Yeonsoo Park, Sang-Man Jin, Choon Hee Chung, Soo Heon Kwak, Jae Hyeon Kim, Gyuri Kim

Diabetes & Metabolism Journal · 04.11.2026

DOI: 10.4093/dmj.2025.1170 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diabetes & Metabolism Journal, online erschienen am 04.11.2026. Verfasst von Jee Hee Yoo und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division of Endocrinology and Metabolism, Department of Medicine, Chung-Ang University Gwangmyeong Hospital, Chung-Ang University College of Medicine….

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

We aimed to investigate factors contributing to discordance between estimated glycosylated hemoglobin (eHbA1c) and measured HbA1c (mHbA1c) from continuous glucose monitoring (CGM) using both 14- and 90-day data in a large Asian cohort.

Methods

We retrospectively analyzed 3,724 14-day and 2,664 90-day glycemic profiles with ≥70% active CGM time (AT) from 1,028 individuals with type 1 diabetes mellitus (T1DM). eHbA1c was calculated using a regression model derived from our study population. Discordance was defined as eHbA1c-mHbA1c (overestimation [eHbA1c ≥ mHbA1c] or underestimation [eHbA1c < mHbA1c]). Similarity was defined as a difference within ±0.1%.

Results

The 14-day eHbA1c model explained 74.7% of the variance in mHbA1c, compared with 88.4% for the 90-day eHbA1c model (conditional R2). Absolute discordance was significantly lower in real-time CGM (rtCGM) than in intermittently scanned CGM (isCGM) (P=0.004), and in those with higher time in range (TIR) and AT (all P

Schlagwörter

Stichwörter der Autor:innen

Asian peopleBlood glucoseContinuous glucose monitoringDiabetes mellitus, type 1Glycated hemoglobin

Autor:innen und Institutionen

  • Division of Endocrinology and Metabolism, Department of Medicine, Chung-Ang University Gwangmyeong Hospital, Chung-Ang University College of Medicine, Gwangmyeong, Korea.
  • Division of Endocrinology and Metabolism, Department of Medicine, Yonsei University Wonju College of Medicine, Wonju, Korea.
  • Division of Endocrinology and Metabolism, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
  • Department of Medical Epidemiology and Biostatistics, Karolinska Institutet, Stockholm, Sweden.
  • Division of Endocrinology and Metabolism, Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Korea.
  • Division of Endocrinology and Metabolism, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea. jaehyeon@skku.edu.

Zitieren

APA

Yoo, J. H., Kim, S., Park, Y., Jin, S. M., Chung, C. H., Kwak, S. H., Kim, J. H., & Kim, G. (2026). Determinants of Discordance between Estimated and Measured HbA1c: The Role of Active Time in 14-Day Continuous Glucose Monitoring Data. Diabetes & Metabolism Journal. https://doi.org/10.4093/dmj.2025.1170

Vancouver

Yoo JH, Kim S, Park Y, Jin SM, Chung CH, Kwak SH, et al. Determinants of Discordance between Estimated and Measured HbA1c: The Role of Active Time in 14-Day Continuous Glucose Monitoring Data. Diabetes & Metabolism Journal. 2026. doi:10.4093/dmj.2025.1170

BibTeX
@article{Yoo2026,
  author = {Yoo, Jee Hee and Kim, Seohyun and Park, Yeonsoo and Jin, Sang-Man and Chung, Choon Hee and Kwak, Soo Heon and Kim, Jae Hyeon and Kim, Gyuri},
  title = {Determinants of Discordance between Estimated and Measured HbA1c: The Role of Active Time in 14-Day Continuous Glucose Monitoring Data},
  journal = {Diabetes & Metabolism Journal},
  year = {2026},
  doi = {10.4093/dmj.2025.1170}
}
Kostenlos starten →