EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyseOpen Access · CC BY-NC 4.0

Diagnostic accuracy of wearable technologies for atrial fibrillation detection: a systematic review and meta-analysis

Alina Abbas, Gauhar Hamid, Beesham Kumar, Sajida Moiz Hussain Qamari, Hira Riaz

Global Cardiology · 19.10.2026 · 4 (3)

DOI: 10.4081/cardio.2026.120 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Global Cardiology, online erschienen am 19.10.2026. Verfasst von Alina Abbas und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia and a major cause of ischemic stroke. Because AF is frequently paroxysmal and asymptomatic, conventional short-term monitoring often fails to detect it. Wearable technologies have emerged as promising tools for AF screening, but their diagnostic performance requires comprehensive evaluation. We conducted a systematic review and diagnostic test accuracy meta-analysis following PRISMA-DTA guidelines. PubMed, Embase, and the Cochrane Library were searched from inception to 25 February 2026 for prospective and retrospective studies using electrocardiographic reference standards. Bivariate random-effects and Bayesian hierarchical models were used to pool diagnostic accuracy estimates. Fifty-one studies involving 33,374 participants from 15 countries were included. PPG-based smartwatches demonstrated the highest sensitivity (96.3%) with specificity of 93.6%. ECG-based smartwatches achieved sensitivity of 89.0% and specificity of 92.8% (DOR 103.9). Smartphone-based ECG devices showed the strongest overall diagnostic performance, with sensitivity of 94.5%, specificity of 95.8%, DOR of 396.4, LR+ of 22.6, and LR− of 0.057. Smartphone-based PPG applications achieved sensitivity of 92.0% and specificity of 91.9%. Apple Watch demonstrated sensitivity of 94.1% and specificity of 94.6%. Meta-regression revealed no statistically significant differences in diagnostic accuracy between device categories despite slightly higher point estimates for PPG-based smartwatches. No significant publication bias was detected (Deeks' test, p=0.18). Wearable devices demonstrate excellent diagnostic accuracy for AF detection, particularly smartphone-based ECG applications. These technologies support scalable AF screening and monitoring, although heterogeneity in study populations and diagnostic thresholds should be considered when applying these findings to routine clinical practice.

Zitieren

APA

Abbas, A., Hamid, G., Kumar, B., Qamari, S. M. H., & Riaz, H. (2026). Diagnostic accuracy of wearable technologies for atrial fibrillation detection: a systematic review and meta-analysis. Global Cardiology, 4(3). https://doi.org/10.4081/cardio.2026.120

Vancouver

Abbas A, Hamid G, Kumar B, Qamari SMH, Riaz H. Diagnostic accuracy of wearable technologies for atrial fibrillation detection: a systematic review and meta-analysis. Global Cardiology. 2026;4(3). doi:10.4081/cardio.2026.120

BibTeX
@article{Abbas2026,
  author = {Abbas, Alina and Hamid, Gauhar and Kumar, Beesham and Qamari, Sajida Moiz Hussain and Riaz, Hira},
  title = {Diagnostic accuracy of wearable technologies for atrial fibrillation detection: a systematic review and meta-analysis},
  journal = {Global Cardiology},
  year = {2026},
  volume = {4},
  number = {3},
  doi = {10.4081/cardio.2026.120}
}
Kostenlos starten →