EUVIMEDEUVIMED entdecken
Crossref

Moisture Control in High Reliability Devices: Correlation of Internal Vapor Analysis and Water Sorption Isotherms for Getter Design Optimization

Alessio Corazza, Luca Mauri, Giovanni Zafarana, Giulia Lezzani, Federico Gallino

IMAPSource Proceedings · 27.10.2026 · 2026 (Symposium)

DOI: 10.4071/001c.173323 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IMAPSource Proceedings, online erschienen am 27.10.2026. Verfasst von Alessio Corazza und 4 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Moisture is one of the most critical contaminants affecting the long-term reliability of hermetically sealed electronic and optoelectronic devices. Excessive internal water vapor can promote corrosion phenomena, leakage currents, electrochemical migration, component delamination, MEMS stiction and optical degradation inside the packages. For this reason, the microelectronics industry has traditionally adopted a maximum internal moisture concentration of 5000 ppmv as a reliability limit for hermetic devices. This work presents a methodology combining Internal Vapor Analysis (IVA), performed on packaged units according to MIL-STD-883 Method 1018, with water sorption isotherms measured on zeolite-based moisture getter coatings, to enable quantitative determination of the getter saturation level and prediction of equilibrium moisture concentration at actual device operating temperatures. The novelty is the direct, quantitative conversion of a standard IVA result obtained at 100°C into getter loading, residual sorption margin, and device-specific moisture concentration at the actual operating temperature; this closes the gap between compliance-oriented gas analysis and predictive getter design. Four case studies involving sealed electronic packages subjected to accelerated aging at elevated temperatures are presented. The results demonstrate that moisture concentration measurements obtained at 100°C during IVA, as prescribed by MIL-STD-883, cannot be directly interpreted without considering getter thermodynamics, related isotherms and device operating temperature. Across the four cases, IVA water concentration values from 1995 to 40000 ppmv corresponded to getter saturation levels from 50% to 77%; the predicted in-service moisture level ranged from approximately 220 ppmv at room temperature to more than 8000 ppmv at 80°C. Devices equipped with properly dimensioned moisture getter can maintain water vapor concentrations well below the critical threshold even at relatively high operation temperature after extended aging. Conversely, devices in which the getter is not adequately designed, may exhibit critical moisture levels. The results underline the importance of combining moisture sorption modeling with IVA measurements during package design and demonstrate that getter sizing should be based on expected lifetime water load and maximum operating temperature rather than solely on initial moisture content.

Zitieren

APA

Corazza, A., Mauri, L., Zafarana, G., Lezzani, G., & Gallino, F. (2026). Moisture Control in High Reliability Devices: Correlation of Internal Vapor Analysis and Water Sorption Isotherms for Getter Design Optimization. IMAPSource Proceedings, 2026(Symposium). https://doi.org/10.4071/001c.173323

Vancouver

Corazza A, Mauri L, Zafarana G, Lezzani G, Gallino F. Moisture Control in High Reliability Devices: Correlation of Internal Vapor Analysis and Water Sorption Isotherms for Getter Design Optimization. IMAPSource Proceedings. 2026;2026(Symposium). doi:10.4071/001c.173323

BibTeX
@article{Corazza2026,
  author = {Corazza, Alessio and Mauri, Luca and Zafarana, Giovanni and Lezzani, Giulia and Gallino, Federico},
  title = {Moisture Control in High Reliability Devices: Correlation of Internal Vapor Analysis and Water Sorption Isotherms for Getter Design Optimization},
  journal = {IMAPSource Proceedings},
  year = {2026},
  volume = {2026},
  number = {Symposium},
  doi = {10.4071/001c.173323}
}
Kostenlos starten →