EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Outcomes of Revision Modified Broström Procedure with Periosteal Flap Augmentation in Patients with Recurrent Chronic Ankle Instability

Jong Jin Moon iD, Myeong Jun Song iD, Jun Young Lee iD

Clinics in Orthopedic Surgery · 2026

DOI: 10.4055/cios26081 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinics in Orthopedic Surgery, 2026. Verfasst von Jong Jin Moon und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Chosun University College of Medicine, Gwangju, Korea. Hauptthemen laut MEDLINE: Joint Instability, Surgical Flaps, Reoperation, Ankle Joint. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Chosun University Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Although the modified Broström procedure (MBP) is widely accepted as the standard surgical treatment for chronic ankle instability (CAI), recurrent instability remains a clinical challenge, particularly in patients with poor tissue quality or high functional demands. To overcome these limitations, periosteal flap augmentation has been proposed as a biological alternative for patients with recurrent CAI after failed MBP. This study evaluated the clinical and radiographic outcomes of revision MBP with periosteal flap augmentation.

Methods

Fourteen patients (mean age, 29.5 years; range, 18-45 years) who underwent revision MBP combined with periosteal flap augmentation between 2018 and 2023 were retrospectively reviewed. The mean follow-up duration was 23.7 months (18-32 months). Clinical outcomes were assessed using the visual analog scale (VAS), American Orthopaedic Foot and Ankle Society (AOFAS) score, and Karlsson-Peterson score. Radiographic evaluation included talar tilt angle and anterior talar displacement.

Results

At a mean follow-up of 23.7 months (18-32 months), all clinical scores improved significantly (VAS: 5.9 to 1.6; AOFAS: 64.1 to 90.6; Karlsson-Peterson: 50.7 to 90.0; p < 0.001). Radiographic stability also improved significantly (talar tilt: 10.7° to 4.9°; anterior displacement: 8.9 mm to 4.1 mm; p < 0.001). No recurrent instability was observed. Three patients had minor wound complications, all of which resolved with conservative treatment.

Conclusions

Revision MBP with periosteal flap augmentation showed favorable short-term clinical and radiographic outcomes in patients with recurrent CAI after failed MBP. This technique may serve as a useful autologous reinforcement option in selected revision cases.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Joint InstabilitySurgical FlapsReoperationAnkle JointPeriosteumHumansAdultFemaleMaleMiddle AgedRetrospective StudiesAdolescentYoung AdultRecurrenceTreatment OutcomeChronic Disease

Stichwörter der Autor:innen

AnkleAnkle jointJoint instabilityLateral ligamentPeriosteumReoperation

Autor:innen und Institutionen

  • Department of Orthopedic Surgery, Chosun University College of Medicine, Gwangju, Korea.

ORCID-Profile: Jong Jin Moon, Myeong Jun Song, Jun Young Lee

Förderung

  • Chosun University Hospital

Zitieren

APA

Moon, J. J., Song, M. J., & Lee, J. Y. (2026). Outcomes of Revision Modified Broström Procedure with Periosteal Flap Augmentation in Patients with Recurrent Chronic Ankle Instability. Clinics in Orthopedic Surgery. https://doi.org/10.4055/cios26081

Vancouver

Moon JJ, Song MJ, Lee JY. Outcomes of Revision Modified Broström Procedure with Periosteal Flap Augmentation in Patients with Recurrent Chronic Ankle Instability. Clinics in Orthopedic Surgery. 2026. doi:10.4055/cios26081

BibTeX
@article{Moon2026,
  author = {Moon, Jong Jin and Song, Myeong Jun and Lee, Jun Young},
  title = {Outcomes of Revision Modified Broström Procedure with Periosteal Flap Augmentation in Patients with Recurrent Chronic Ankle Instability},
  journal = {Clinics in Orthopedic Surgery},
  year = {2026},
  doi = {10.4055/cios26081}
}
Kostenlos starten →