EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Improving Reliability of Immunological Assays by Defining Minimal Criteria for Cell Fitness

Sabine Ivison, Gabrielle Boucher, Grace Zheng, Rosa V Garcia iD, Rita Kohen iD, Alain Bitton, John D Rioux iD, Megan K Levings iD, iGenoMed Consortium

ImmunoHorizons · 01.09.2024 · 8 (9) · 622-634

DOI: 10.4049/immunohorizons.2300095 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ImmunoHorizons, online erschienen am 09.09.2024. Verfasst von Sabine Ivison und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, University of British Columbia, Vancouver, British Columbia, Canada. Hauptthemen laut MEDLINE: Leukocytes, Mononuclear, Cryopreservation, Cell Survival, Flow Cytometry. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 66 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Human PBMC-based assays are often used as biomarkers for the diagnosis and prognosis of disease, as well as for the prediction and tracking of response to biological therapeutics. However, the development and use of PBMC-based biomarker assays is often limited by poor reproducibility. Complex immunological assays can be further complicated by variation in cell handling before analysis, especially when using cryopreserved cells. Variation in postthaw viability is further increased if PBMC isolation and cryopreservation are done more than a few hours after collection. There is currently a lack of evidence-based standards for the minimal PBMC viability or “fitness” required to ensure the integrity and reproducibility of immune cell–based assays. In this study, we use an “induced fail” approach to examine the effect of thawed human PBMC fitness on four flow cytometry–based assays. We found that cell permeability-based viability stains at the time of thawing did not accurately quantify cell fitness, whereas a combined measurement of metabolic activity and early apoptosis markers did. Investigation of the impact of different types and levels of damage on PBMC-based assays revealed that only when cells were >60–70% live and apoptosis negative did biomarker values cease to be determined by cell fitness rather than the inherent biology of the cells. These data show that, to reproducibly measure immunological biomarkers using cryopreserved PBMCs, minimal acceptable standards for cell fitness should be incorporated into the assay protocol.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Leukocytes, MononuclearCryopreservationCell SurvivalFlow CytometryHumansReproducibility of ResultsBiomarkersApoptosis

Substanzen

Biomarkers

Autor:innen und Institutionen

  • Department of Surgery, University of British Columbia, Vancouver, British Columbia, Canada.
  • BC Children's Hospital Research Institute, Vancouver, British Columbia, Canada.
  • Montreal Heart Institute, Montreal, Quebec, Canada.
  • McGill University Health Centre, Montreal, Quebec, Canada.
  • Department of Medicine, Université de Montréal, Montreal, Quebec, Canada.
  • Department of Biochemistry and Molecular Medicine, Université de Montréal, Montreal, Quebec, Canada.

ORCID-Profile: Rosa V Garcia, Rita Kohen, John D Rioux, Megan K Levings

Zitieren

APA

Ivison, S., Boucher, G., Zheng, G., Garcia, R. V., Kohen, R., Bitton, A., Rioux, J. D., Levings, M. K., & iGenoMed Consortium (2024). Improving Reliability of Immunological Assays by Defining Minimal Criteria for Cell Fitness. ImmunoHorizons, 8(9), 622-634. https://doi.org/10.4049/immunohorizons.2300095

Vancouver

Ivison S, Boucher G, Zheng G, Garcia RV, Kohen R, Bitton A, et al. Improving Reliability of Immunological Assays by Defining Minimal Criteria for Cell Fitness. ImmunoHorizons. 2024;8(9):622-634. doi:10.4049/immunohorizons.2300095

BibTeX
@article{Ivison2024,
  author = {Ivison, Sabine and Boucher, Gabrielle and Zheng, Grace and Garcia, Rosa V and Kohen, Rita and Bitton, Alain and Rioux, John D and Levings, Megan K and iGenoMed Consortium, iGenoMed Consortium},
  title = {Improving Reliability of Immunological Assays by Defining Minimal Criteria for Cell Fitness},
  journal = {ImmunoHorizons},
  year = {2024},
  volume = {8},
  number = {9},
  pages = {622--634},
  doi = {10.4049/immunohorizons.2300095}
}
Kostenlos starten →