EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 3.0

The Diagnostic Value of Positron Emission Tomography in Detecting the Breast Cancer

Dong Young Noh, Ik Jin Yun, Han Sung Kang, Ji Soo Kim, Dong Soo Lee, June Key Chung, Myung Chul Lee, Yeo Kyu Youn, Seung Keun Oh, Kuk Jin Choe

Journal of Korean Breast Cancer Society · 1998

DOI: 10.4048/jkbcs.1998.1.1.6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Korean Breast Cancer Society, 1998. Verfasst von Dong Young Noh und 9 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

z~~ .~QjE2 . ~ef~ . EJAI'i>' OI~'i>1 ~~711 . OI~~1 . ~ofrr' 2.~2:' ~~E Positron Emission Tomography (PET) is a new imaging method employing radionuclide and tomography technique. In breast cancer PET has high sensitivity in detecting primary tumor and axillary node metastasis. From 1995 June to 1996 November, 27 patients had undergone breast operations following PET under impression of breast cancer in Seoul National University Hospital (SNUH). Whole body PET images were obtained beginning 60 minutes after infection of 370 MBq (10 mCi) F-18 FDG (fluorodeoxy glucose). Regional scans were also obtained with trans­ mission images. We compared PET results with those of physical examination and mammography. All cases were histologically confinned. For primary tumor mass, diagnostic accuracy of PET was excellent (97%) compared whh the physical examination (78%) and mammography (67%), For axillary lymph node metastasis, PET ~':? an outs,tanding detection accuracy (96%), compared with the physical examination and mammography (74%, 60%, respectively). And whole body PET scan made it possible to see the all metastatic lesions at a glance in cases of metastatic or recurred breast cancer. There was likely correlation between Standard Uptake Value (SUV) and the number of axillary lymph node metastasis, but in this study, statistical significance was not proven because of small number of cases. PET also could detect breast cancer in paraffin augmented breast. We concluded that PET is very sensitive and accurate diagnostic tool for breast cancer and SUV, after more studies, could be used as an important prognostic factor. (Korean J of Breast Cancer 1998;1:6-12)

Zitieren

APA

Noh, D. Y., Yun, I. J., Kang, H. S., Kim, J. S., Lee, D. S., Chung, J. K., Lee, M. C., Youn, Y. K., Oh, S. K., & Choe, K. J. (1998). The Diagnostic Value of Positron Emission Tomography in Detecting the Breast Cancer. Journal of Korean Breast Cancer Society. https://doi.org/10.4048/jkbcs.1998.1.1.6

Vancouver

Noh DY, Yun IJ, Kang HS, Kim JS, Lee DS, Chung JK, et al. The Diagnostic Value of Positron Emission Tomography in Detecting the Breast Cancer. Journal of Korean Breast Cancer Society. 1998. doi:10.4048/jkbcs.1998.1.1.6

BibTeX
@article{Noh1998,
  author = {Noh, Dong Young and Yun, Ik Jin and Kang, Han Sung and Kim, Ji Soo and Lee, Dong Soo and Chung, June Key and Lee, Myung Chul and Youn, Yeo Kyu and Oh, Seung Keun and Choe, Kuk Jin},
  title = {The Diagnostic Value of Positron Emission Tomography in Detecting the Breast Cancer},
  journal = {Journal of Korean Breast Cancer Society},
  year = {1998},
  doi = {10.4048/jkbcs.1998.1.1.6}
}
Kostenlos starten →