EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

An Approach to Develop a Diagnostic Reference Level in Gamma Camera Imaging for Bone Scan

Anjali Kaveesha, Vijitha Ramanathan, Ranga Tudugala

Sri Lanka Journal of Medical Sciences · 29.03.2026 · 1 (2)

DOI: 10.4038/sljms1.v1i2.13 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sri Lanka Journal of Medical Sciences, online erschienen am 29.03.2026. Verfasst von Anjali Kaveesha und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Among many imaging procedures performed in a Gamma Camera Unit, bone scan is the most abundantly performed procedure. A diagnostic reference level (DRL) is an effective tool to optimize radiation exposure to patients and staff while maintaining the adequate diagnostic image quality. The aim of this study is to optimize the patient radiation dose by establishing a DRL for gamma camera imaging for bone scan performed at two hospitals in Colombo, Sri Lanka. A total of 134 imaging procedures was selected for this study. 84 gamma camera imaging procedures were collected from Apeksha Hospital, Maharagama (Hospital No.1) and 50 procedures were collected from Asiri Surgical Hospital, Colombo (Hospital No.2), from September 2022 to November 2022. According to the recommendation of the International Commission of Radiological Protection (ICRP), the median value of the administered activity value was considered to develop DRL. The median values of the administered activity for the two hospitals were 587 MBq for Hospital No.1and 586 MBq for Hospital No.2. The developed DRL values for bone scan in gamma camera imaging are 587 MBq (15.865 mCi) for Hospital No.1 and 586 MBq (15.839 mCi) for Hospital No.2. There is a 0.026 mCi difference in administered activity observed between two institutes. There were significant correlations were observed between the administered activity and patient’s body mass index, and between the administered activity and patient’s clinical indication. KEYWORDS: Gamma camera, Diagnostic reference level, Bone scan, Administered activity

Zitieren

APA

Kaveesha, A., Ramanathan, V., & Tudugala, R. (2026). An Approach to Develop a Diagnostic Reference Level in Gamma Camera Imaging for Bone Scan. Sri Lanka Journal of Medical Sciences, 1(2). https://doi.org/10.4038/sljms1.v1i2.13

Vancouver

Kaveesha A, Ramanathan V, Tudugala R. An Approach to Develop a Diagnostic Reference Level in Gamma Camera Imaging for Bone Scan. Sri Lanka Journal of Medical Sciences. 2026;1(2). doi:10.4038/sljms1.v1i2.13

BibTeX
@article{Kaveesha2026,
  author = {Kaveesha, Anjali and Ramanathan, Vijitha and Tudugala, Ranga},
  title = {An Approach to Develop a Diagnostic Reference Level in Gamma Camera Imaging for Bone Scan},
  journal = {Sri Lanka Journal of Medical Sciences},
  year = {2026},
  volume = {1},
  number = {2},
  doi = {10.4038/sljms1.v1i2.13}
}
Kostenlos starten →