EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Predictive Value of Pulse Oximetry – Derived Perfusion Index for Hypotension After Spinal Anesthesia for Elective Caesarean Deliveries: A Prospective Study

S. Nethra, H. D. Arun Kumar, Aditya R. Devalla, Malavika Kulkarni

Sri Lankan Journal of Anaesthesiology · 30.01.2026 · 34 (1) · 115-123

DOI: 10.4038/slja.v34i1.9486 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sri Lankan Journal of Anaesthesiology, online erschienen am 30.01.2026. Verfasst von S. Nethra und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The study aims to determine if baseline perfusion index can be used to predict hypotension following spinal anesthesia in elective lower segment caesarean delivery (LSCS) and to find the correlation between baseline perfusion index and incidence of hypotension following spinal anesthesia in parturients undergoing LSCS.Material and Methods: A prospective, single-center observational study was conducted on parturients aged 20 to 35 years scheduled for elective LSCS, recruited based on specific inclusion and exclusion criteria.

Results

The mean age of the participants was 31.15 ± 2.70 years, with a mean baseline perfusion index (PI) of 3.45. The majority (62.5%) achieved a sensory blockade level of T6 five minutes after spinal anesthesia. Approximately 68.8% experienced hypotension. A baseline PI of ≥3.5 was significantly associated with increased incidence of hypotension (p = 0.004), and the PI showed moderate sensitivity (57.58%) and high specificity (86.67%) for predicting hypotension. ROC analysis showed an AUC of 0.775 (p = 0.002), and a moderate positive correlation (r = 0.484, p < 0.001) was observed between baseline PI and the number of doses of vasopressor administered.

Conclusion

Baseline perfusion index (PI) at a cutoff value of 3.5 can be reliably used as a valuable predictor of hypotension in parturients undergoing caesarean delivery under spinal anesthesia, with a positive predictive value of 91 % and diagnostic accuracy of 67 %.

Zitieren

APA

Nethra, S., Kumar, H. D. A., Devalla, A. R., & Kulkarni, M. (2026). Predictive Value of Pulse Oximetry – Derived Perfusion Index for Hypotension After Spinal Anesthesia for Elective Caesarean Deliveries: A Prospective Study. Sri Lankan Journal of Anaesthesiology, 34(1), 115-123. https://doi.org/10.4038/slja.v34i1.9486

Vancouver

Nethra S, Kumar HDA, Devalla AR, Kulkarni M. Predictive Value of Pulse Oximetry – Derived Perfusion Index for Hypotension After Spinal Anesthesia for Elective Caesarean Deliveries: A Prospective Study. Sri Lankan Journal of Anaesthesiology. 2026;34(1):115-123. doi:10.4038/slja.v34i1.9486

BibTeX
@article{Nethra2026,
  author = {Nethra, S. and Kumar, H. D. Arun and Devalla, Aditya R. and Kulkarni, Malavika},
  title = {Predictive Value of Pulse Oximetry – Derived Perfusion Index for Hypotension After Spinal Anesthesia for Elective Caesarean Deliveries: A Prospective Study},
  journal = {Sri Lankan Journal of Anaesthesiology},
  year = {2026},
  volume = {34},
  number = {1},
  pages = {115--123},
  doi = {10.4038/slja.v34i1.9486}
}